Skip to main content
Siemens 5SJ4101-8HG41

Siemens 5SJ4101-8HG41 SENTRON MCB, 1P, D-curve, 10kA/15kA

MPN 5SJ4101-8HG41
Active

Siemens SENTRON 5SJ4 series, miniature circuit breaker, 1-pole, D tripping characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 18 mm width, IP20/IP40.

$38.10 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SJ4101-8HG41 specifications
ParameterValue
Poles1
Mountingon standard mounting rail
Depth70 mm
Width18 mm
Height110 mm

Product details

What it is and where it fits

The Siemens 5SJ4101-8HG41 is a 1-pole SENTRON miniature circuit breaker from the 5SJ4 series, designed with a D tripping characteristic. It protects branch circuits in control panels and distribution boards against overload and short-circuit, rated for 400 V AC and 60 V DC. The D curve means it tolerates high inrush currents — typical for motor starters, transformers, or welding equipment — without nuisance tripping, while still clearing faults at its rated breaking capacities. Rated for pollution degree 3 and overvoltage category III, meaning it's suited for fixed industrial installations where conductive contamination is possible (e.g., machine enclosures, panel interiors). IP20 with conductors connected; IP40 in the handle area — enough for enclosed panels, not for washdown zones.

Breaking capacity and selectivity

This breaker carries two breaking-capacity ratings: 10 kA per EN 60898 (household-type MCB standard) and 15 kA per IEC 60947-2 (industrial standard). The higher IEC figure is the one that governs panel SCCR coordination in an industrial line — it means the breaker can safely interrupt a 15 kA prospective fault at 400 V AC without upstream devices needing to clear first. For DC circuits, the maximum rated voltage is 60 V DC. The D characteristic (10–20× In magnetic trip) pairs well with loads that draw a brief inrush several times the rated current — think motor contactors, solenoid banks, or power supplies. For purely resistive or lightly inductive loads, a B or C curve would trip faster; the D curve is the right call where nuisance trips on start-up are the main concern.

Lifecycle and sourcing

Production status is current — this is an active catalog item, not a phase-out or NRND line. The 5SJ4 series remains Siemens' standard offering for panel-protection in the SENTRON family. Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
5SJ4101-8HG41