Mitsubishi Electric FR-D720-0.2K-CHT
MPNFR-D720-0.2K-CHT
Easy Small inverter FREQROL - D 700 series Three phase 200 V
$194.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| Type | Easy · Small inverters FREQROL-D 700 series Three-phase 200V |
| Product series | FREQROL-D 700 |
| Voltage | 3 phase 200~240V |
| Power supply voltage class | Three-phase 200V class |
| AC voltage allowable variation | 170 to 264 V 50 Hz / 60 Hz |
| Rated input AC voltage · frequency | 3 phase 200 ~ 240 V 50 Hz / 60 Hz |
| Voltage (frequency characteristics) | Base frequency 0 to 400 Hz Optional setting, constant torque · reduction Torque pattern selectable |
| Current | 1.4 |
| Overload current rating | 150% 60 s, 200% 0.5 s (at inverse time characteristic) |
| Applicable motor capacity | 0.2 kW |
| Power supply equipment capacity | 0.7 |
| Frequency accuracy | Analog input : Within ± 1% of maximum output frequency (25 °C ± 10 °C) |
All specifications+39 ▾
| Parameter | Value |
|---|---|
| Output frequency range | 0.2 to 400 Hz |
| Frequency setting signal | Number of analog input terminals : 2 points |
| Frequency setting resolution | Analog input : 0.06 Hz / 60 Hz (Terminal 4: 0 to 20 mA / 10 bits), 0.06 Hz / 60 Hz (Terminals 2, 4: 0 to 10 V / 10 bits), 0.12 Hz / 60 Hz (Terminals 2 and 4: 0 to 5 V / |
| Frequency tolerance variation | ± 5% |
| Input terminal selectable signal | External thermal input, PU - external operation switching, V / F switching, output stop, start self-holding selection, positive terminal selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal Pr. 178 to Pr. 182 (input terminal function selection) arbitrary signal from the external interlock of the PU operation, PU operation, PU operation, changeover command, inverter reset, PUNET operation changeover, external-NET operation changeover, Select by |
| Output terminal selectable signal | During inverter operation, frequency reached, overload alarm, output frequency detection, regenerative brake pre alarm, electronic thermal pre alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation Safety monitor output, Safety monitor output 2, Retrying, Lifetime alarm, Current average value monitor, Remote output, Minor fault output , Abnormal output, abnormal output 3, maintenance timer alarm, selected by Pr. 190, Pr. 192, Pr. 197 (output terminal function selection). |
| Analog input terminal specification | Terminal 2: 0 to 10 V, 0 to 5 V selectable, terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable |
| Number of output terminals (relay output) | 1point |
| Display meter output terminal specification | FM: Up to 2.4 kHz |
| Number of display terminal output terminals | 1point |
| Display meter output terminal selectable signal | Output frequency, Output current (steady state), Output voltage, Frequency setting value, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Reference voltage output, Motor load factor, PID Pulse train output (1440 pulses / s / full scale) is selected by Pr.54 FM terminal function selection, target value, PID measured value, output power, PID deviation, motor thermal load factor, |
| Output terminal selectable signal (when option is installed) | Can not install built-in option |
| Output signal | Output terminal (open collector output) Number of points : 1point |
| Environment ambient temperature | -10 °C to + 50 °C (no freezing) (-10 °C to + 40 °C when fully closed structure specifications) |
| Ambient humidity | 90% RH or less (no condensation) |
| Shipping weight | 1.5 Kg |
| Atmosphere | Indoor (no corrosive gas, flammable gas, oil mist, dust) |
| DC braking | Operating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable |
| Input signal | Number of terminal points (contact input) : 5 points |
| Manufacturer | Mitsubishi Electric |
| Start signal | Individual normal rotation / reverse rotation, start signal self-holding input (3 wire input) selectable |
| Torque boost | Manual torque boost |
| Digital input | Input by operation panel, parameter unit, frequency setting unit selectable |
| Cooling method | Self-cooling |
| Starting torque | 150% or more (at 1 Hz) When slip correction is set by general-purpose magnetic flux vector control |
| Abnormal content | Abnormality content is displayed during operation of protection function, 8 times of abnormality content is memorized (output voltage, current, frequency, total energization time immediately before protection function operation) |
| Product model name | FR-D720-0.2K |
| Estimated lead time | Usually ships in 1-10 working days. |
| Storage temperature | -20 °C to + 65 °C |
| Approximate mass | 0.5 |
| Display control panel | Operating condition : Output frequency, Output current (steady state), Output voltage, Frequency set value, Integrated energization time, Actual operating time, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Motor Selectable from load factor, PID target value, PID measurement value, PID deviation, inverter input / output terminal monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance value |
| Protection (alarm function) | Overcurrent during acceleration, overcurrent during deceleration, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, deceleration Overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheating, At startup Output side ground fault current, output phase loss, external thermal operation, PTC thermistor operation, parameter error, PU missing occurrence, over retry count, CPU abnormality, brake transistor abnormality, inrush resistance overheat, analog input abnormality, stop due to stall prevention , Overcurrent stall prevention, Over-voltage stall prevention, PU stop, Parameter write error, Regenerative brake pre-alarm, Electronic thermal pre-alarm, Maintenance output, Undervoltage, Operation Panel lock, Password setting, Inverter resetting, Safety Stopped |
| Regenerative braking torque | Maximum value · Allowable usage rate : - |
| Output rated capacity | 0.6 |
| Protective structure (JEM 1030) | Closed type (IP 20), fully closed structure series is IP 40. |
| Stall prevention operation level | Operating current level selectable (0 to 200% variable), selectable |
| Control specification control method | Soft-PWM control / high carrier frequency PWM control (V / F control, general magnetic flux vector control, optimum excitation control can be selected) |
| Acceleration (deceleration time setting) | 0.1 ~ 3600 s (Individual acceleration / deceleration setting possible), linear or S-shaped acceleration / deceleration mode selectable |
| Operating specification driving function | Upper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip correction, operation mode selection, offline auto tuning Function, PID control, Computer link operation (RS - 485), Optimum excitation control, Power outage stop, Speed ??smoothing control, Modbus - RTU |
MPN
FR-D720-0.2K-CHT