Skip to main content
Mitsubishi Electric FR-E840-0120-4-60 — AC Drive (VFD) 480V

Mitsubishi FR-E840-0120-4-60 Inverter, 400 V class

MPNFR-E840-0120-4-60

Mitsubishi, FR-E800 series inverter, 400 V class three-phase input, ND-rated slot 0120, conformal-coated PCB without plated conductors, order code FR-E840-0120-4-60.

$764.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

FR-E840-0120-4-60 — Specifications
ParameterValue
4400 V class
-4Monitoring/protocol specifications : Voltage (terminal AM)Rated frequency (initial setting) : 50 HzInput signal (initial status) : Source logicSafety stop signal : Source logic (fixed)
-60Circuit board coating : With coatingPlated conductor : Without plated conductors
0120Inverter ND rated current (A)
NoneThree-phase input
Weight2.4 Kg
Product typeInverter FR-E800
Plated conductorWithout plated conductors
Safety stop signalSource logic (fixed)
Circuit board coatingWith coating
Input signal (initial status)Source logic
Rated frequency (initial setting)50 Hz
Monitoring (protocol specifications)Voltage (terminal AM)

Product details

What the suffix strip means for the wiring bench

The FR-E840-0120-4-60: For a controls integrator, that sets the bench expectation — the safe-stop input expects a sourcing signal and is not reconfigurable, and the digital inputs default to source logic so sinking sensors need a parameter flip before commissioning.

Sourcing posture for the BOM line

With lifecycle marked current and no official successor code in the record, the procurement move is to specify the FR-E840-0120-4-60 into the BOM as quoted-to-order and let the RFQ drive lead time and authorised-channel confirmation.

Frequently asked questions

Is the FR-E840-0095-4-60 a direct second source for the FR-E840-0120-4-60?

No — it is the next-smaller ND-rated slot in the same 400 V class, conformal-coated -60 build and same AM/50 Hz/source-logic monitoring bundle, but the output rating and mounting footprint differ, so a panel designed around the 0095 needs a re-check rather than a straight swap.

What does the '4' in FR-E840-0120-4-60 mean?

It marks the 400 V input class, paired with three-phase input on this build.

What does the '-4' suffix bundle define?

It sets the monitoring defaults: terminal AM as the voltage analog output, initial rated frequency 50 Hz, input signal source logic, and safety stop signal source logic (fixed).

MPN
FR-E840-0120-4-60