Omron E2AS08KS01WPB1TP5MOMS Inductive Sensor, M8 Flush, 1mm,

MPNE2AS08KS01WPB1TP5MOMS

Omron E2A series inductive proximity sensor, M8 flush mount, NO output, 1 mm sensing distance, 10-32 VDC, 200 mA, IP67/IP69K, stainless steel housing, 3-pin stranded wire.

$99.60Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2AS08KS01WPB1TP5MOMS — Identification
ParameterValue
SeriesE2A
E2AS08KS01WPB1TP5MOMS — Sensing
ParameterValue
Sensing distance, max.1 mm
E2AS08KS01WPB1TP5MOMS — Electrical
ParameterValue
Operating voltage, max.32 V
Operating voltage, min.10 V
Termination typeStranded Wire, 3-Pin
E2AS08KS01WPB1TP5MOMS — Output
ParameterValue
Load current200 mA
E2AS08KS01WPB1TP5MOMS — Mechanical
ParameterValue
Mounting typeFlush Mount
Length40 mm
Housing materialStainless Steel
E2AS08KS01WPB1TP5MOMS — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
IP protection ratingIP67;IP69K

Product details

Fit and function

The Omron E2AS08KS01WPB1TP5MOMS is a flush-mount M8 inductive proximity sensor with a 1 mm sensing distance, normally-open output, and a 200 mA load rating over 10–32 VDC. The 1 mm range is intentionally tight—it suits applications where you detect small ferrous targets at a fixed gap, such as position confirmation on a pick-and-place gripper or a cam-lobe presence check, without false triggers from adjacent metal.

Rugged enough for washdown

The stainless steel housing and IP67/IP69K rating let this sensor survive high-pressure, high-temp washdown cycles typical in food processing or pharmaceutical filling lines. The 10 % repeat accuracy on a 1 mm sensing distance keeps the switch point consistent over temperature.

How it sits beside the 2 mm sibling

The electrical envelope—10–32 VDC, 200 mA, NO output—is shared with the 2 mm sensing distance variant E2AS08KS02WPD12MOMS, and the M8 flush-mount body is identical. The critical difference for a panel already wired for the 2 mm three-pin version is that this unit comes with stranded 3-pin wiring, while the 2 mm peer uses a 2-pin termination. If your existing harness expects two wires (brown and blue only, signal and power on the same pair), replacing with this 3-pin NO sensor will require a third wire for the normally-open signal return. Same footprint, different wiring scheme.

Frequently asked questions

Can I drop this unit into a panel wired for E2AS08KS02WPD12MOMS without rewiring?

Not directly. Both share the same M8 footprint and electrical ratings, but the 2 mm version uses a 2-pin stranded wire while this part uses 3-pin. The extra wire (normally-open signal) must be present in the harness or the output will not register. Verify your existing cable termination before swapping.