Skip to main content
Omron E5EC-TQX4A5M-010 — Process / Temperature Controllers

Omron E5EC-TQX4A5M-010 Temperature Controller

MPNE5EC-TQX4A5M-010
Active

Omron E5EC-T, Process / Temperature Controller, E5EC-TQX4A5M-010, 4 Relay + Voltage (External SSR) outputs, universal input, IP66 front panel.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

E5EC-TQX4A5M-010 — Identification
ParameterValue
SeriesE5EC-T
TypeProcess, Temperature Controller (RTD, Type B, E, J, K, L, N, PLII, R, S, T, U, W)
E5EC-TQX4A5M-010 — Electrical
ParameterValue
Supply voltage100 ~ 240VAC
E5EC-TQX4A5M-010 — Performance
ParameterValue
Control methodOn/Off, Proportional (PID)
FeaturesEvent Input, Heater Fault Detection
E5EC-TQX4A5M-010 — I/O
ParameterValue
Input range-200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC
Output typeRelay (4), Voltage (External SSR)
E5EC-TQX4A5M-010 — Display
ParameterValue
Display typeLCD - Tri Color Characters, Backlight
Characters per row4, 4, 4
Character height0.710" (18.00mm), 0.433" (11.00mm), 0.307" (7.80mm)
E5EC-TQX4A5M-010 — Environmental
ParameterValue
Operating temperature-10°C ~ 55°C
Ingress protection (IP rating)IP66 - Dust Tight, Water Resistant
E5EC-TQX4A5M-010 — Mechanical
ParameterValue
Mounting typePanel Mount
Panel cutout dimensionsRectangular - 92.00mm x 45.00mm
Termination styleScrew Terminal
E5EC-TQX4A5M-010 — Other specifications
ParameterValue
Weight0.463 lb (210.01 g)

Product details

Universal input, four relay outputs

The Omron E5EC-TQX4A5M-010 is a panel-mount process and temperature controller from the E5EC-T series. It accepts a wide range of inputs — RTD, thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, plus 0–20 mA and 0–10 VDC process signals — so one part number covers most loop types on a machine. Outputs are four relay contacts plus a voltage pulse for driving an external SSR. That gives you three alarm or event outputs plus the main control output, or two stages of heating/cooling with alarms.

The cutout is 92.00 mm × 45.00 mm, the standard 1/4 DIN horizontal format. Screw-terminal connections on the rear; no special tooling needed for installation. The front panel carries an IP66 rating — dust-tight and protected against hose-down. Suitable for food-processing or washdown zones where a standard controller would fail from moisture ingress through the bezel.

Heater fault detection and event input

Built-in heater fault detection monitors the load current via an external CT and flags a broken heater or SSR short before the process drifts out of spec. The event input lets a PLC or limit switch remotely switch the controller between two setpoints or start/stop control.

Frequently asked questions

Is the E5EC-TQX4A5M-010 obsolete?

No. The lifecycle status is active. No successor or replacement has been announced.

How do I wire the Omron E5EC-TQX4A5M-010?

Termination is via screw terminals on the rear of the unit. The wiring diagram is in the product manual; the heater fault CT connects to dedicated terminals, and the event input is a dry-contact between two terminals. Confirm the specific pinout against the manual for your application.

MPN