Skip to main content
Omron K8AC-H21PN-FLK — Process / Temperature Controllers

Omron K8AC-H21PN-FLK Heater Element Detector, 0.20~2.20A

MPNK8AC-H21PN-FLK
Active

Omron K8AC-H series heater element detector, order code K8AC-H21PN-FLK, input range 0.20 ~ 2.20A, solid-state outputs, RS-485 CompoWay/F, DIN rail mount, 85 ~ 264VAC supply.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

K8AC-H21PN-FLK — Identification
ParameterValue
SeriesK8AC-H
TypeHeater Element Detector
K8AC-H21PN-FLK — Electrical
ParameterValue
Supply voltage85 ~ 264VAC
K8AC-H21PN-FLK — I/O
ParameterValue
Input range0.20 ~ 2.20A
Output typeSolid State (2)
K8AC-H21PN-FLK — Communication
ParameterValue
Communication interfacesRS-485 (CompoWay/F)
K8AC-H21PN-FLK — Performance
ParameterValue
FeaturesHeater Fault Detection
K8AC-H21PN-FLK — Display
ParameterValue
Display typeLED - Red Characters
Characters per row4
K8AC-H21PN-FLK — Environmental
ParameterValue
Operating temperature-10°C~55°C
K8AC-H21PN-FLK — Mechanical
ParameterValue
Mounting typeDIN Rail
Termination styleSpring Terminal
K8AC-H21PN-FLK — Other specifications
ParameterValue
Weight0.441 lb (200.03 g)

Product details

What it catches and why it matters

The Omron K8AC-H21PN-FLK is a dedicated heater element detector — it monitors the current drawn by a resistive heating load and flags a fault when the current drops outside the set window, meaning a broken heater element or a failed SSR that leaves the load unpowered. The input range of 0.20 ~ 2.20 A covers small to mid-size heaters typical in injection molding, packaging seal bars, and process ovens.

DIN-rail integration and communication

Mounts on standard DIN rail (snap-on) and terminates via spring terminals — no screw tightening, which speeds panel wiring and stays tight under vibration. The RS-485 interface uses Omron's CompoWay/F protocol, so the detector reports heater current and fault status to a PLC or HMI over a two-wire bus without running separate alarm wires back to the controller.

Power and environment

Runs on 85 ~ 264 VAC supply. The 4-digit red LED display shows the measured current in real time.

Frequently asked questions

Does K8AC-H21PN-FLK have RS-485 communication?

Yes, it supports RS-485 using the CompoWay/F protocol, allowing the detector to report current and fault status to a PLC or HMI over a two-wire bus.

MPN
K8AC-H21PN-FLK