Siemens 3RT2036-1AH04

Siemens 3RT2036-1AH04 SIRIUS Power Contactor, 52 A at 480 V

MPN 3RT2036-1AH04
Active

Siemens SIRIUS power contactor, Size S2, 3RT2036-1AH04, screw-type terminals, 52 A at 480 V AC-3, snap-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RT2036-1AH04 specifications
ParameterValue
Depth174 mm
Width55 mm
Height114 mm
Arcing time10 ... 20 ms

Product details

What the 52 A at 480 V rating means for your motor circuit

The Siemens 3RT2036-1AH04 is a SIRIUS Size S2 power contactor rated 52 A at 480 V — that is the AC-3 motor-switching current, meaning it handles a 3-phase induction motor drawing up to 52 A during starting and running, without welding the main contacts on inrush. For a 480 V supply, that translates to roughly a 30–40 hp motor, depending on the exact full-load current curve. The contactor snaps onto a 35 mm DIN rail per DIN EN 60715 and measures 55 mm wide by 114 mm high by 174 mm deep — the 174 mm depth is the dimension that matters most when planning gland-plate clearance or a shallow enclosure back-panel.

Mounting and integration — DIN rail, screw terminals, position flexibility

The 6 mm side gap is tighter than the vertical ones — plan the DIN-rail spacing accordingly to avoid heat buildup between adjacent contactors. Main contact arrangement is 3-pole (18...1 designation), and the coil terminals are screw-type. Wire capacity accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded.

Maximum operating frequency varies by duty: 1,000 cycles/hour at AC-1 (resistive), 800 at AC-3 (motor start/run), 600 at AC-2 (slip-ring motor), and 250 at AC-4 (plugging/inching). The AC-3e rating matches the AC-3 figure at 800 cycles/hour. If your application involves frequent jogging or reversing, the AC-4 limit of 250 cycles/hour is the governing spec — exceeding it accelerates contact wear. Arcing time is 10 to 20 ms, and the make/break time at AC is 10 to 18 ms. These are fast enough for most motor-control circuits but matter for coordination with upstream short-circuit protection — the arc clears before the breaker's instantaneous trip can see the fault current.

Lifecycle and sourcing — active production, quoted to order