Siemens 3RV2021-4AA10-0RT0

Siemens 3RV2021-4AA10-0RT0 Motor Protection CB, Size S0, 25

MPN 3RV2021-4AA10-0RT0

Siemens SIRIUS 3RV2 motor protection circuit breaker, Size S0, 3RV2021-4AA10-0RT0, 25 kA rated breaking capacity at 400 V AC, Class 10 trip, screw terminals, 45 mm wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV2021-4AA10-0RT0 specifications
ParameterValue
Depth97 mm
Width45 mm
Height97 mm
Trip classCLASS 10

Product details

Size S0 motor protection breaker — 25 kA at 400 V, Class 10

The Siemens 3RV2021-4AA10-0RT0 is a Size S0 motor protection circuit breaker from the SIRUS 3RV2 family, designed for screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715. Rated breaking capacity hits 25 kA at 400 V AC (55 kA at 400 V AC for the main circuit) and 100 kA at 240 V AC, giving solid SCCR headroom for most industrial motor branch circuits without cascading upstream. The Class 10 trip characteristic matches standard IEC motor starting profiles — it holds through the inrush and clears on a locked-rotor fault without nuisance tripping. Motor power rating is 4 kW at 230 V, with a maximum AC-3 operating voltage of 690 V. The gG fuse backup ratings are 63 A at 400 V, 50 A at 500 V, and 40 A at 690 V — coordination data for selective coordination studies. Mechanical endurance is listed at 100 000 typical cycles for the main contacts.

The 25 kA at 400 V rated breaking capacity and 55 kA at 400 V for the main current circuit mean this breaker can safely interrupt high fault currents in a 400 V distribution panel — typical for European 400 V three-phase motor branch circuits. These figures are the SCCR the breaker contributes to the panel assembly; coordination with upstream fuses or breakers uses the gG backup ratings provided. Trip Class 10 means the breaker's thermal overload element allows a motor to draw locked-rotor current for up to 10 seconds before tripping — enough for most standard induction motor starts, but not for high-inertia loads that need Class 20 or Class 30. The 15 1/h maximum switching rate at AC-3 duty matches typical process cycling, not high-speed jogging. No ground fault or phase failure detection built in — this is a basic motor protection breaker for overload and short-circuit only. If phase loss or ground fault protection is required, add an external relay or specify a variant with those functions.

For panel builders or MRO planners, the screw-type main circuit terminals accept 2x (1 to 2.5 mm²) or 2x (2.5 to 10 mm²) solid or stranded copper — covers most motor feeder sizes up to 4 kW at 230 V. The M4 main contact screws and Pozidriv size 2 screwdriver tip are standard panel tools.

Integration notes

The 45 mm width occupies one standard 45 mm module slot. Clearance requirements: 50 mm upwards, 50 mm downwards, 30 mm at the sides, zero forwards and backwards. The breaker is designed for any mounting position, so it can be installed horizontally or vertically in tight enclosures without derating the thermal trip.

MPN
3RV2021-4AA10-0RT0