Skip to main content
Omron E5EC-TRX4A5M-008

Omron E5EC-TRX4A5M-008 Process/Temp Controller

MPN E5EC-TRX4A5M-008
Active

Omron E5EC-TRX4A5M-008 process/temperature controller, E5EC-T series, 5 relay outputs, RS-485 CompoWay/F Modbus, 100-240 VAC, IP66 front panel, panel mount 92x45 mm cutout.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-TRX4A5M-008 specifications
ParameterValue
SeriesE5EC-T
Output signalRelay (5)
Supply voltage100 to 240VAC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

Five relay outputs and universal input for multi-zone control

This E5EC-TRX4A5M-008 carries five relay outputs — enough to drive a three-stage heater bank plus an alarm and a cooling fan, all from one controller. The universal input accepts RTD, nine thermocouple types (B, E, J, K, L, N, R, S, T, U, W), plus 0-20 mA or 0-10 VDC process signals, so it covers everything from a 200°C oven to a 2300°C furnace. The RS-485 port speaks both CompoWay/F and Modbus protocols — tie it into a PLC or SCADA network without a protocol converter. On/Off or PID control method is selectable per loop; the tri-color LCD shows three rows of four characters each, with the largest digits at 18 mm high readable from across a panel.

IP66 front panel and heater fault detection for wet process areas

The front face carries an IP66 rating — dust-tight and protected against hose-directed water, which makes this controller a candidate for food processing, washdown stations, or outdoor cabinet installations. The event input and heater fault detection feature monitors current draw on electric heaters and flags a broken element or SSR short before the process drifts. Operating range is -10°C to 55°C, so it lives inside a non-conditioned enclosure in most plant-floor environments. The panel cutout is 92.00 mm x 45.00 mm — the standard 1/4 DIN footprint — and it mounts with screw terminals that accept up to 14 AWG field wiring.

Active production, sourced per BOM quantity

This part is quoted to order against your BOM line; availability and current pricing are confirmed at RFQ time through authorized distribution channels.

MPN
E5EC-TRX4A5M-008