Siemens 4EM5008-0DK00

Siemens 4EM5008-0DK00 Commutating Choke, 20A, 2.2mH, 690V

MPN 4EM5008-0DK00

Siemens 4EM5008-0DK00 commutating choke for converters, single-phase, AC, 690V rated voltage, 20A max AC current, 2.2mH inductance, IP00, screw/tab terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EM5008-0DK00 specifications
ParameterValue
IP ratingIP00
Depth0.115 m
Width0.097 m
Height0.111 m

Product details

The Siemens 4EM5008-0DK00 is a single-phase commutating choke (line reactor) designed for converter front-ends. It limits current rise during switching events, reducing harmonic distortion and protecting the DC link from line notches. Rated for 690 V AC at 60 Hz, it carries 20 A maximum AC current and delivers 2.2 mH inductance with a 2.4% relative inductive voltage drop at rated load. That 2.4% drop is the key sizing figure — it tells you the choke is matched to the converter's impedance budget, so swapping in a different value shifts the voltage sag and can trip the drive on undervoltage.

This choke is IP00 — no enclosure, no finger-safe cover. It mounts inside a panel, typically on a base plate or DIN rail via an optional bracket (not included). Dimensions are 0.115 m deep, 0.097 m wide, 0.111 m tall, so it fits in a standard 200 mm deep enclosure with room for gland plates and wiring ducts. Terminals are screw-type or tab connections, accepting solid or stranded copper up to the rated current. The thermal class B (130 °C) insulation system means the winding can run hot without degrading — fine for a 40 °C ambient, but if your panel ambient pushes past that, derate the continuous current or add forced ventilation.

The 20 A maximum AC current is the thermal limit (Ith) — the choke can carry that continuously in free air at 40 °C. The 18 A rated operational current (I_LN) is the design point for the 2.4% voltage drop; running at 20 A pushes the drop higher and increases core saturation, so the 18 A figure is the one to use for sizing against your converter's nominal input current. Power loss splits into 14.3 W in the winding (copper) and 25.8 W in the iron core — total 40.1 W dissipated as heat inside the panel.

MPN