A9KR13225S — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9KR13225S — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)440 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemGroup incomer
Electrical durabilityAC-1: 4000 cycles
Mechanical durability (operating cycles)5000 cycles
A9KR13225S — Identification
ParameterValue
Product nameActi9 ID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameID K
A9KR13225S — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsBiconnect top or bottom 1...35 mm² rigid Biconnect top or bottom 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth68 mm
A9KR13225S — Environmental
ParameterValue
Operating ambient temperature-5...55 °C
Storage ambient temperature-25...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9KR13225S — Approvals
ParameterValue
StandardsEN/IEC 61008-1 SS 97:part 1

Product details

The Schneider Electric A9KR13225S is an Acti9 ID K residual current circuit breaker (RCCB) — a 2-pole, 25 A device with 30 mA earth-leakage sensitivity, rated for 220-240 V AC 50 Hz networks.

Depth of 68 mm and height of 81 mm keep the profile compact; verify gland-plate clearance if the enclosure has a shallow back-can depth. IP20 finger-safe terminals; IP40 when installed in a modular enclosure — suitable for dry indoor panels only, not washdown or outdoor locations.

Connection and wiring

Biconnect terminals top and bottom accept 1-35 mm² rigid or 1-25 mm² flexible conductors; strip length 14 mm, tighten to 3.5 N·m.

Certified to EN/IEC 61008-1 and SS 97:part 1, with SAFETY Mark quality label. Rated insulation voltage 440 V AC; impulse withstand 200 A (8/20 µs) per EN/IEC 61008-1. Pollution degree 2 — clean indoor environment assumed.

Frequently asked questions

What compliance documentation does Schneider provide for A9KR13225S?

The part carries EN/IEC 61008-1 and SS 97:part 1 certification, SAFETY Mark, and tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and UL documentation, request the manufacturer's declaration from your sourcing contact.