Skip to main content
Schneider Electric A9KR13240 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9KR13240 Acti9 ID K RCCB, 40A 30mA 2P

MPNA9KR13240
Obsolete

Schneider Electric Acti9 ID K, Residual current circuit breaker (RCCB), 2P, 40 A, 30 mA, Type AC, 220-240 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9KR13240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9KR13240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)220...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)440 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemGroup incomer
Electrical durabilityAC-1: 4000 cycles
Mechanical durability (operating cycles)5000 cycles
A9KR13240 — Identification
ParameterValue
Product nameActi9 ID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameID K
A9KR13240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsBiconnect top or bottom 1...35 mm² rigid Biconnect top or bottom 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth68 mm
A9KR13240 — Environmental
ParameterValue
Operating ambient temperature-5...55 °C
Storage ambient temperature-25...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9KR13240 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 SS 97:part 1

Product details

The Schneider Electric A9KR13240 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 ID K series, rated at 40 A with 30 mA earth-leakage sensitivity. The 30 mA sensitivity (Type AC) covers sinusoidal AC residual currents, which is the standard protection level for general-purpose socket-outlet circuits and final subcircuits in residential and commercial panels. The instantaneous trip time means no intentional delay — it clears a ground fault as soon as the leakage exceeds threshold.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715). Neutral is on the left. Biconnect terminals top and bottom accept 1-35 mm² rigid or 1-25 mm² flexible cable; strip length 14 mm, tighten to 3.5 N·m. IP20 on the front face (finger-safe), IP40 within the modular enclosure once installed. Pollution degree 2 — suitable for normal indoor environments where only non-conductive pollution occurs.

The operational voltage (Ue) is 220-240 V AC — this is the coil/line-to-neutral voltage it expects. Electrical durability is 4000 cycles under AC-1 resistive load; mechanical durability is 5000 cycles. For a fixed RCCB in a distribution board that sees infrequent manual operation, this is adequate — it's not a switching device cycled daily. The 8/20 µs impulse withstand of 200 A means it survives common lightning-induced surge currents without nuisance tripping.

Compliance documentation includes EN/IEC 61008-1 (the RCCB product standard) and SS 97:part 1 (Singapore standard). Carries SAFETY Mark quality label. No UL or CSA listing — this part is designed for IEC markets primarily.

Frequently asked questions

What is A9KR13240 used for?

It is a residual current circuit breaker (RCCB) for AC circuits, rated 40 A with 30 mA sensitivity, used to protect against earth leakage faults in residential and commercial distribution boards. It is a group incomer device, meaning it can serve as the main RCCB feeding multiple downstream MCBs.

Where can I buy A9KR13240?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation — submit an RFQ for a firm commercial offer.

What are the key specifications of A9KR13240?

2-pole, 40 A rated current, 30 mA earth-leakage sensitivity, Type AC (sinusoidal residual currents only), voltage-independent tripping, instantaneous trip, 220-240 V AC 50 Hz operational voltage, clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches).

MPN