Skip to main content
Schneider Electric A9R51425 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R51425 Acti9 iID RCCB, 25 A, 30 mA, 4P

MPNA9R51425
Active

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 4P, 25 A, 30 mA, Type A, 380-415 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R51425 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R51425 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R51425 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R51425 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R51425 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R51425 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R51425 is an Acti9 iID residual current circuit breaker (RCCB) — a 4-pole, voltage-independent device rated for 25 A continuous current and 30 mA earth-leakage sensitivity.

The 30 mA sensitivity (Type A) detects sinusoidal AC and pulsating DC residual currents — the standard for general-purpose socket-outlet and lighting circuits in residential and commercial panels. The 25 A rating matches the incoming feed for a sub-distribution board or a heavy appliance circuit. Instantaneous trip (no intentional delay) means it clears earth faults immediately, so selectivity with upstream time-delay RCCBs or RCBOs must be checked during coordination study. Rated breaking capacity Idm 1500 A covers most final-circuit fault conditions within a domestic or light commercial installation. The insulation voltage (Ui) of 500 V AC and impulse withstand (Uimp) of 6 kV give headroom for transient overvoltages common on TN and TT systems.

MPN