Schneider Electric A9R51263

Schneider Electric A9R51263 Acti9 iID RCCB, 63A 30mA Type A,

MPN A9R51263
Active

Schneider Electric Acti9 iID, RCCB, 2P, 63 A, 30 mA, Type A, 220-240 V AC, DIN rail, EN/IEC 61008-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R51263 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R51263 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID series, designed for AC networks at 50/60 Hz. It protects against earth-leakage faults with a sensitivity of 30 mA — the standard threshold for personal shock protection in residential and commercial final circuits. The 63 A rated current (In) suits main incomers or high-load sub-distribution boards where the full load current passes through the device.

Voltage-independent tripping means the device clears a fault even if the line voltage is lost, a safety advantage over electronically-triggered RCDs. The instantaneous time delay provides no intentional delay, so it trips within the IEC 61008-1 standard response window, which is correct for socket-outlet and general-purpose circuits where fast disconnection is required. Breaking and making capacity is rated at Idm 1500 A and Im 1500 A, which covers the prospective fault current typical at the outgoer position in a domestic or light commercial distribution board. The surge current withstand of 250 A (8/20 µs impulse) means it tolerates lightning-induced or switching transients without nuisance tripping, a practical concern on overhead-supplied installations. Insulation voltage (Ui) is 500 V AC, giving headroom for system voltage variations.

Neutral is on the left; verify orientation before wiring. Terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable; strip length 14 mm. Tightening torque 3.5 N.m. IP20 on the device body, IP40 inside a modular enclosure — suitable for panel mounting, not for wet-area standalone use.

Designed and certified to EN/IEC 61008-1, the harmonized standard for residual current operated circuit-breakers without integral overcurrent protection.