Skip to main content
Schneider Electric A9R51463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R51463 Acti9 iID RCCB, 63 A, 30 mA, 4P

MPNA9R51463
Active

Schneider Electric Acti9 iID RCCB, A9R51463, 4P, 63 A, 30 mA, Type A, 400 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R51463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R51463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)400 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R51463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R51463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R51463 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R51463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R51463 is an Acti9 iID residual current circuit breaker (RCCB) — 4 poles, rated 63 A, with a 30 mA earth-leakage sensitivity. It's a Type A device, so it catches sinusoidal AC faults and pulsating DC faults up to 6 mA smooth DC — covers most modern electronics and single-phase rectified loads without nuisance tripping.

The rated breaking and making capacity is Idm 1500 A / Im 1500 A; that's the short-circuit withstand of the RCCB itself (not a breaker's interrupting rating, but enough to survive a fault until an upstream MCB clears it). Surge current withstand is 250 A (8/20 µs impulse), conforming to EN/IEC 61008-1, so it won't trip on lightning-induced spikes or capacitive inrush. IP20 on the body, IP40 inside a modular enclosure: fine for dry indoor panels, not for washdown areas.

Clip-on mounting to DIN rail, 9 mm pitches: 8 modules wide (72 mm). Neutral is on the left — verify busbar orientation before assembly. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible; wire stripping length is 14 mm. Padlocking provision for lockout/tagout.

Frequently asked questions

How do I get current pricing and availability for A9R51463?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is A9R51463's earth-leakage sensitivity and type?

30 mA, Type A (sinusoidal AC and pulsating DC fault detection), instantaneous trip, voltage-independent tripping technology.

What standards does A9R51463 comply with?

EN/IEC 61008-1 for residual current circuit breakers. Pollution degree 3, IP20/IP40. Ambient operating range -25 to 60 °C.

MPN