Skip to main content
Schneider Electric A9R55225 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R55225 Acti9 iID K RCCB, 25 A, 30 mA, 2

MPNA9R55225
Active

Schneider Electric Acti9 iID K, A9R55225, Residual Current Circuit Breaker (RCCB), 2P, 25 A, 30 mA, Type AC, 4500 A Inc.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R55225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R55225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Electrical durabilityAC-1: 2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R55225 — Identification
ParameterValue
Product nameActi9 iID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID K
A9R55225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...35 mm² rigid Tunnel type terminals top or bottom 1...25 mm² flexible Tunnel type terminals top or bottom 1...25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height85 mm
Depth69 mm
A9R55225 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
A9R55225 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9R55225 is a 2-pole (2P) Residual Current Circuit Breaker (RCCB) from the Acti9 iID K series, rated for 25 A continuous current with a 30 mA earth-leakage sensitivity. Because the tripping technology is voltage-independent, the device operates without an external power supply — it will still trip on a residual fault even if the line voltage collapses, a key reliability factor for safety circuits. Rated operational voltage is 220...240 V AC at 50/60 Hz, with a rated insulation voltage of 440 V AC and an impulse withstand voltage of 4 kV. The conditional short-circuit current (Inc) is 4500 A, and the rated breaking and making capacity (Idm/Im) is 500 A. These figures define the fault-clearing capability in the downstream circuit.

Standards, approvals, and compliance

It carries the NF quality label.

Installation and wiring constraints

Terminals are tunnel-type, accepting 1...35 mm² rigid wire or 1...25 mm² flexible (with or without ferrule) for top or bottom connection. The toggle control provides manual on/off and test functionality. Electrical durability is rated at 2000 cycles under AC-1 resistive load, and mechanical durability at 5000 cycles. The device has no contact position indicator but accepts a padlocking device for lockout/tagout.

For BOM-line commitment, the active lifecycle status and standard product class mean no last-time-buy urgency, but the 30 mA Type AC RCCB is a high-volume item — lead times are generally stable through normal supply routes.

Frequently asked questions

How do I get current pricing and availability for the A9R55225?

The A9R55225 is sourced and quoted to order against an RFQ. Submit a request through the distributor's quotation system; availability and current pricing are confirmed at quote time.

What is the closest alternative to the A9R55225 in the Acti9 family?

Within the Acti9 iID range, the primary variant difference is sensitivity (30 mA vs 100 mA or 300 mA) and pole count (2P vs 4P). The A9R55225 is a 2P, 25 A, 30 mA, Type AC RCCB. A Type A variant (detecting pulsating DC) would be needed for circuits with single-phase rectified loads like washing machines or LED drivers. No pin-compatible drop-in with different sensitivity or type is listed as a direct successor; select based on the downstream load profile.

What compliance documentation does the A9R55225 carry?

The A9R55225 is certified to EN/IEC 61008-1 and EN/IEC 61008-2-1, and carries the NF quality label. Standard documentation includes the manufacturer's declaration of conformity to the applicable EU directives (Low Voltage Directive, EMC Directive). RoHS and REACH compliance is standard for Schneider Electric Acti9 products.

MPN
A9R55225