Schneider Electric C10H3TM063C — Miniature Circuit Breakers (MCB)

C10H3TM063C ComPacT NSX100H 63A 3P Thermal-Magnetic MCCB, 10

MPNC10H3TM063C
Active

Schneider Electric ComPacT NSX100H, 3-pole 63 A thermal-magnetic MCCB, TM-D trip unit, 100 kA Icu at 240 V AC, toggle control, IP40, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10H3TM063C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10H3TM063C — Ratings
ParameterValue
Rated current (In)63 A at 50 °C
Poles configuration3P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10H3TM063C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10H3TM063C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10H3TM063C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10H3TM063C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10H3TM063C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 'H' breaking capacity code means it delivers 100 kA Icu at 220/240 V AC and 70 kA at 380/415 V AC — headroom that keeps fault energy contained within the device rather than cascading upstream. That matters for a distribution board where the transformer or bus rating is set at 65 kA; this breaker clears faults well above that level without coordination loss. Rated 63 A at 50 °C. Power dissipation is 8.61 W per pole. IP40 enclosure protection keeps out tools and fingers; IK07 impact rating handles incidental knocks during panel assembly.

Integration notes for the panel builder

The 35 mm connection pitch matches standard busbar systems and cable lug spacing. Five accessory slots on the front accept auxiliary contacts, shunt trips, or alarm switches without increasing the breaker footprint. Mounts flat on the backplate in either horizontal or vertical orientation. Front terminals on both line and load sides simplify busbar routing and cable dressing in a multi-breaker lineup. Toggle handle provides manual ON/OFF with clear visual indication. Electrical durability: 50,000 cycles at 440 V at rated current, 30,000 cycles at 440 V at In. Mechanical durability matches at 50,000 cycles. Suitable for isolation per EN/IEC 60947-2 — a lockable handle option (not included) would be needed for lockout/tagout compliance.

Frequently asked questions

What is C10H3TM063C's breaking capacity at 415 V AC?

The C10H3TM063C delivers 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, which is the 'H' breaking capacity code rating.

What compliance standards does the C10H3TM063C meet?

The C10H3TM063C complies with EN/IEC 60947-2 for circuit-breaker performance, IEC 60664-1 for pollution degree 3, and IEC 60529 for IP40 protection. It is certified for isolation per EN/IEC 60947-2.