Schneider Electric C10R4TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C10R4TM080 ComPacT NSX Circuit Breaker, 8

MPNC10R4TM080
Active

Schneider Electric ComPacT NSX circuit breaker, 4P, 80 A thermal-magnetic TM-D trip unit, 200 kA Icu at 415 V AC, EN/IEC 60947-2.

$13.71Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10R4TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10R4TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration4P
Breaking capacity200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)200 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10R4TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C10R4TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10R4TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10R4TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10R4TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What the 80 A TM-D trip unit and 200 kA Icu mean for your distribution panel

The C10R4TM080 is a Schneider Electric ComPacT NSX circuit breaker with a 4-pole frame, an 80 A thermal-magnetic TM-D trip unit, and an R-breaking-capacity rating of 200 kA Icu at 415 V AC. The TM-D trip unit combines a thermal bimetal for overload protection (L) and a magnetic coil for short-circuit protection (I), both adjustable within the trip unit's range. At 690 V AC the Icu is still 45 kA, covering most industrial line-to-line voltages.

Mounting and integration into a panel

IK07 impact resistance handles accidental tool drops during commissioning.

MPN