Skip to main content
Schneider Electric C11B4TM100B — Miniature Circuit Breakers (MCB)

Schneider Electric C11B4TM100B ComPacT NSXm MCCB, 100A 4P 25

MPNC11B4TM100B
Active

Schneider Electric ComPacT NSXm, C11B4TM100B, 4P thermal-magnetic MCCB, 100 A at 40 °C, 25 kA at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11B4TM100B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11B4TM100B — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11B4TM100B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11B4TM100B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11B4TM100B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11B4TM100B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11B4TM100B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11B4TM100B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The thermal-magnetic trip unit (TM-D) provides overload protection via a bimetal element and short-circuit protection via a solenoid, both factory-set and non-interchangeable.

Deployment context

Mounts on a backplate (not DIN rail) in horizontal or vertical orientation. Front-front connections accept compression lugs or busbars, with a 35 mm connection pitch (27 mm without spreaders). The 12-module 9 mm pitch footprint — 108 mm wide, 137 mm high, 80 mm deep — fits standard distribution panel layouts.

Operating altitude 2000 m without derating, 5000 m with derating. Relative humidity range 0–95 %. Electrical durability: 20,000 cycles at 440 V at In/2, 10,000 cycles at 440 V at In. Mechanical durability: 20,000 cycles.

Frequently asked questions

What is the breaking capacity of the C11B4TM100B?

The C11B4TM100B has a performance level B breaking capacity of 25 kA at 415 V AC. This is the maximum fault current it can safely interrupt at that voltage.

What standards does the C11B4TM100B comply with?

It complies with EN/IEC 60947-2 for low-voltage switchgear. It also meets pollution degree 3 per IEC 60664-1 and overvoltage category III.

Where can I buy the C11B4TM100B and get current pricing?

The C11B4TM100B is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN