Schneider Electric C11H4TM100B — Miniature Circuit Breakers (MCB)

Schneider C11H4TM100B ComPacT NSXm 100A 4P 70kA MCCB

MPNC11H4TM100B
Active

Schneider Electric ComPacT NSXm, circuit breaker, 100 A at 40 °C, 4P, 70 kA 415 V AC, thermal-magnetic TM-D trip unit, IP40, grey (RAL 7016).

$675.27Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H4TM100B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H4TM100B — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H4TM100B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11H4TM100B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H4TM100B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H4TM100B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H4TM100B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11H4TM100B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C11H4TM100B is a ComPacT NSXm moulded-case circuit breaker rated 100 A at 40 °C, 4-pole, with a 70 kA interrupting capacity at 415 V AC (H performance level). It uses a thermal-magnetic TM-D trip unit for overcurrent and short-circuit protection on distribution networks.

The TM-D trip unit is fixed thermal-magnetic — no interchangeable rating plugs. Use it for cable/ busbar protection, switchboard feeders, or distribution sub-mains. Pollution degree 3 (IEC 60664-1) and overvoltage category III mean it is rated for fixed industrial installations where conductive pollution or transient overvoltages (e.g. from upstream switching) are expected — typical for a main distribution panel in a factory, not a clean-room control cabinet.

Physical integration

Mounts on a backplate (not DIN rail) — the 108 mm wide, 137 mm high, 80 mm deep footprint occupies 12 module pitches at 9 mm each. Connection is front-to-front via compression lugs or busbars; neutral is on the left. The IP40 enclosure and IK07 impact rating suit enclosed panel mounting where tools or dropped parts may strike the breaker face.

Mechanical endurance is 20,000 cycles; electrical endurance is 20,000 cycles at 440 V at rated current (In/2) and 10,000 cycles at In — figures that matter for a breaker that sees regular switching, not just fault protection.

Frequently asked questions

What is C11H4TM100B's interrupting rating?

70 kA at 415 V AC (H performance level), certified under IEC 60947-2.

What trip unit does C11H4TM100B use?

A fixed thermal-magnetic TM-D trip unit rated 100 A at 40 °C — no interchangeable rating plugs.

Where can I buy C11H4TM100B and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
C11H4TM100B