Skip to main content
Schneider Electric C11H4TM100L — Miniature Circuit Breakers (MCB)

Schneider Electric C11H4TM100L ComPacT NSXm 100A 4P Circuit

MPNC11H4TM100L
Active

Schneider Electric ComPacT NSXm, C11H4TM100L, 100 A at 40 °C, 4P, 70 kA at 415 V AC, thermal-magnetic trip unit, EN/IEC 60947-2.

$377.85Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H4TM100L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H4TM100L — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H4TM100L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11H4TM100L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11H4TM100L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H4TM100L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H4TM100L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11H4TM100L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 100 A rating at 40 °C means it protects distribution feeders and branch circuits up to that continuous current without nuisance tripping in a warm panel.

Mounts on a backplate in any orientation — horizontal, vertical, or flat on the back. The 108 mm width (12 x 9 mm pitches) and 137 mm height fit standard panel cutouts. Front-facing connections top and bottom; neutral is on the left. The Everlink lug terminals accept 2.5 to 95 mm² rigid aluminium or copper, or 2.5 to 70 mm² flexible copper — one lug per pole. Connection pitch is 35 mm with spreaders, 27 mm without. The flag indicator (green) shows presence of auxiliary contacts.

Frequently asked questions

How do I get current pricing and availability for C11H4TM100L?

Submit an RFQ through the storefront. Pricing and availability are confirmed at quote time; the part is sourced to order through independent distribution.

What is C11H4TM100L's breaking capacity?

It is rated 70 kA at 415 V AC, performance level H, per EN/IEC 60947-2.

What compliance documentation does this brand provide for C11H4TM100L?

The breaker is certified to EN/IEC 60947-2 and is suitable for isolation per that standard. Pollution degree 3 and overvoltage category III are declared per IEC 60664-1.

MPN
C11H4TM100L