Schneider Electric C11N6TM040L — Miniature Circuit Breakers (MCB)

C11N6TM040L ComPacT NSXm 40A 4P MCCB, 50 kA at 415 V AC

MPNC11N6TM040L
Active

Schneider Electric ComPacT NSXm, C11N6TM040L, 40 A thermal-magnetic MCCB, 4P, 50 kA at 415 V AC, IP40, grey RAL 7016.

$255.69 – $612.79Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11N6TM040L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11N6TM040L — Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11N6TM040L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11N6TM040L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11N6TM040L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11N6TM040L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11N6TM040L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11N6TM040L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The trip unit is thermal-magnetic (TM-D), meaning the thermal bimetal handles overload protection and the magnetic coil handles short-circuit; the D curve gives a higher magnetic trip threshold (10–14× In) suited for loads with moderate inrush like small motors or transformers.

The 108 mm width × 137 mm height × 80 mm depth fits standard distribution panel layouts; the 12-module 9 mm pitch gives you the DIN-rail footprint count for panel planning. Connection is front-facing on both line and load sides, using Everlink lug terminals that accept 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper. That terminal range covers most distribution feeder and subfeed sizes. The 35 mm connection pitch with spreaders (27 mm without) is the dimension to check when wiring multiple breakers in a row. IP40 enclosure protection means it's suited for indoor panel installation — no washdown rating, so keep it behind the gland plate.

That standard covers the interrupting ratings, isolation suitability (yes, marked as suitable for isolation per IEC 60947-2), and the utilisation category A (non-delayed, for distribution use). Overvoltage category III suits fixed-installation distribution boards. The IK07 impact rating (per IEC 62262) means the enclosure resists 2 J impacts — enough for accidental tool drops during panel work. The grey RAL 7016 colour is the standard Schneider finish for this range. Compliance documentation (declaration of conformity, IEC test reports) is available from Schneider's product documentation portal; the part carries CE marking for the European market.

Frequently asked questions

What is the breaking capacity of C11N6TM040L?

The performance level is N, rated at 50 kA at 415 V AC. That's the maximum fault current the breaker can safely interrupt at that voltage.

What terminals does the C11N6TM040L use and what wire sizes fit?

Everlink lug terminals on both line and load sides. Accepts 2.5…95 mm² rigid or stranded aluminium/copper, and 2.5…70 mm² flexible copper.

Where can I buy C11N6TM040L and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the difference between the NSXm and the full-size NSX?

The NSXm is the compact frame — smaller footprint (108 mm wide vs the NSX's wider frame) and a lower maximum current rating (63 A frame vs 250 A or higher on the NSX). The C11N6TM040L tops out at 40 A; if your load exceeds that, step up to the full-size NSX.