Specifications

C12F4TM160B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C12F4TM160B — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C12F4TM160B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C12F4TM160B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C12F4TM160B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C12F4TM160B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C12F4TM160B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C12F4TM160B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D trip combines a thermal element for overload protection and a magnetic element for short-circuit response — no electronic adjustments, just fixed-curve reliability.

Category A utilisation means it's not intended for cascading (no intentional short-time delay), so selectivity with downstream devices relies on the thermal-magnetic curve gap. Pollution degree 3 (IEC 60664-1) suits it for industrial panels where conductive dust or condensation is expected. IP40 front face keeps tools and fingers out; the backplate mount and front connection terminals suit panel layouts where side access is tight.

Integration notes

Mounts on a backplate in horizontal or vertical orientation. 12-module 9 mm pitch width (108 mm) fits standard DIN-rail-mount enclosures with adapters. Connection terminals accept compression lugs or busbars; neutral position is left. The toggle control and flag indicator for auxiliary contact presence give clear local status without opening the panel door.

Frequently asked questions

Where can I buy C12F4TM160B and how is it quoted?

The C12F4TM160B is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ.

What standards does C12F4TM160B comply with?

The C12F4TM160B complies with EN/IEC 60947-2 for low-voltage switchgear and controlgear, with suitability for isolation per that standard. Pollution degree 3 per IEC 60664-1 and IK07 impact resistance per IEC 62262.

What is the breaking capacity of C12F4TM160B?

The C12F4TM160B is rated 36 kA at 415 V AC (performance level F). That's the maximum fault current it can safely interrupt at that voltage.

What trip unit does C12F4TM160B use?

It uses a TM-D thermal-magnetic trip unit rated 160 A at 40 °C. No electronic adjustments — fixed overload and short-circuit curves.

MPN