Specifications

C16F6TM125 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16F6TM125 — Ratings
ParameterValue
Rated current (In)125 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16F6TM125 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16F6TM125 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16F6TM125 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16F6TM125 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16F6TM125 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The thermal-magnetic trip provides L (overload) and I (short-circuit) protection in one device — no separate relay or CT needed. At 125 A and 40 °C ambient, this is sized for a main feeder or a large motor branch circuit in a 400 V class panel.

At 240 V AC it rises to 85 kA Icu — enough for most North American 240/120 V distribution. The 4-pole version (4P) with neutral left position and 3D neutral protection setting means the neutral pole is not protected — it switches but does not trip. This is standard for distribution where the neutral is bonded at the transformer.

Width 140 mm, height 161 mm, depth 86 mm — fits standard 35 mm connection pitch. IP40 enclosure protection, IK07 impact resistance. Front connections both upside and downside.

Mechanical durability 40,000 cycles. Electrical durability at 440 V In: 20,000 cycles; at 440 V In/2: 40,000 cycles. At 690 V In: 7,500 cycles; at 690 V In/2: 15,000 cycles. Utilisation category A — not intended for frequent switching of motor loads under load (that would be category B or a contactor). This breaker is for distribution and infrequent switching.

Frequently asked questions

What is the breaking capacity of C16F6TM125 at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 240 V AC it is 85 kA Icu; at 690 V AC it is 8 kA Icu.

What trip unit does C16F6TM125 use?

A TM-D thermal-magnetic trip unit rated 125 A at 40 °C, providing L (overload) and I (short-circuit) protection.

Where can I buy C16F6TM125 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Schneider provide for C16F6TM125?

The breaker is certified to EN/IEC 60947-2, UL 60947-4-1, and carries IP40, IK07, and pollution degree 3 ratings. RoHS and REACH declarations are standard from Schneider for this series.