Schneider Electric C16N3TM160C — Miniature Circuit Breakers (MCB)

Schneider Electric C16N3TM160C ComPacT NSX160N, 160A, 50kA 4

MPNC16N3TM160C
Active

Schneider Electric ComPacT NSX, NSX160N, 3P, 160 A, TM-D trip unit, 50 kA at 415 V AC, thermal-magnetic MCCB.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N3TM160C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16N3TM160C — Ratings
ParameterValue
Rated current (In)160 A at 50 °C
Poles configuration3P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16N3TM160C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16N3TM160C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16N3TM160C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16N3TM160C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16N3TM160C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C16N3TM160C is a ComPacT NSX160N molded-case circuit breaker with a 160 A TM-D thermal-magnetic trip unit, 3 poles, and a 50 kA breaking capacity at 415 V AC (Icu per IEC 60947-2). It's a distribution-grade MCCB for panelboard or backplate mounting, rated for isolation and suited for protecting cable and moderate motor circuits in commercial and industrial switchboards. The 160 A frame at 50 °C means this breaker carries its full rating at elevated panel ambient — no derating needed until you push past that temperature.

The N breaking capacity code delivers 50 kA Icu at 415 V AC, which is the standard high-fault rating for North American 480Y/277 V and European 400 V distribution. That 50 kA at 415 V gives you solid selectivity with upstream 100 kA or 150 kA frames — the NSX160N coordinates cleanly with a ComPacT NS630b or MasterPact MTZ on a typical 800 A transformer secondary. For a 160 A feeder, this is the typical spec for a main breaker in a downstream panel or a large motor branch circuit.

The TM-D trip unit is fixed thermal-magnetic: the L protection (thermal) handles overloads with a time-current curve that tracks cable heating, and the I protection (magnetic) provides instantaneous short-circuit pickup. No electronic adjustment or ground-fault module — this is the straightforward, no-nonsense trip for standard distribution where you don't need LSIG or communication. The 160 A rating at 50 °C is the Ir setting; the magnetic pickup is fixed at roughly 10x In (1600 A), typical for TM-D. Power dissipation runs 13.95 W per pole, so three poles pull about 42 W — factor that into enclosure thermal rise if you're packing multiple breakers in a can.

Front connections both top and bottom — no rear or plug-in option on this variant. The 105 mm width, 161 mm height, and 86 mm depth fit standard MCCB cutouts in switchboard chassis. Connection pitch is 35 mm, matching standard busbar spacing.

Operates at 0–2000 m without derating; above that, derate per IEC 60947-2. Humidity range 0–95% non-condensing. No earth-leakage protection integrated — specify a separate Vigi module or external RCD if needed.

Frequently asked questions

What is the breaking capacity of C16N3TM160C at 415 V?

The C16N3TM160C delivers 50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. This is the N breaking capacity code, which is the standard high-fault rating for 400 V class distribution.

What trip unit does C16N3TM160C use?

It uses a TM-D thermal-magnetic trip unit rated 160 A at 50 °C. The L protection (thermal) handles overloads and the I protection (magnetic) provides instantaneous short-circuit pickup. No electronic adjustment or ground-fault module.

Where can I buy C16N3TM160C and how is it quoted?

The C16N3TM160C is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm quote on your required quantity.

What are the mounting dimensions of C16N3TM160C?

Width 105 mm, height 161 mm, depth 86 mm. Mounts on a backplate in horizontal or vertical orientation. Connection pitch is 35 mm. Front connections top and bottom.

What standards does C16N3TM160C comply with?

Compliant with EN/IEC 60947-2. Suitable for isolation per that standard. Pollution degree 3, overvoltage category III. IP40 front face, IK07 impact resistance. Operating altitude 0–2000 m without derating.