Skip to main content
Schneider Electric C16N6TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C16N6TM080 ComPacT NSX160N, 80 A, 50 kA a

MPNC16N6TM080
Obsolete

Schneider Electric ComPacT NSX160N, 4P, 80 A thermal-magnetic TM-D trip, 50 kA Icu at 415 V AC, toggle control, backplate mount.

$385.02 – $875.02Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16N6TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16N6TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16N6TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16N6TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16N6TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16N6TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16N6TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C16N6TM080 is a Schneider Electric ComPacT NSX160N molded-case circuit breaker in the 4-pole configuration, rated 80 A at 40 °C with a thermal-magnetic TM-D trip unit. The TM-D provides L (thermal) overload protection and I (magnetic) short-circuit protection in one package — no electronic adjustments, just a reliable bimetal and solenoid that has been the workhorse of distribution panels for decades. At 690 V AC the Icu drops to 10 kA, so watch the system voltage when you spec this into a 600 V class panel.

The Icu ratings span the common industrial voltages: 90 kA at 240 V AC, 50 kA at 415 V, 36 kA at 500 V, 35 kA at 525 V, and 10 kA at 690 V. For UL 60947-4-1 applications, the same frame carries 85 kA at 240 V and 50 kA at 480 V. The 80 A trip rating at 40 °C means you need to derate if the ambient in the enclosure runs hotter — standard practice for any MCCB in a sealed panel.

Connection pitch is 35 mm, and the neutral sits on the left in the 4P configuration. IK07 impact resistance handles the occasional dropped screwdriver.

Mechanical durability is 40,000 cycles; electrical durability depends on the load — 40,000 cycles at 440 V at half rated current, 20,000 at full rated current, and 7,500 cycles at 690 V at full current. The toggle control is manual — no motor operator or shunt trip included in this base variant.

Frequently asked questions

What is the breaking capacity of C16N6TM080 at 415 V?

It carries a 50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, which is the N breaking capacity code.

What trip unit does C16N6TM080 use?

It uses a TM-D thermal-magnetic trip unit rated 80 A at 40 °C, providing L (thermal overload) and I (magnetic short-circuit) protection.

How do I get current pricing and availability for C16N6TM080?

Submit an RFQ through this listing — pricing and stock are confirmed at quote time through independent distribution channels.

MPN