Schneider Electric C25F6TM250 — Miniature Circuit Breakers (MCB)

C25F6TM250 ComPacT NSX 250A MCCB, 36kA 415V AC

MPNC25F6TM250
Active

Schneider Electric ComPacT NSX, MCCB, 250 A, 4P, thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC, toggle control, front connections.

$452.17Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25F6TM250 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25F6TM250 — Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25F6TM250 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25F6TM250 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C25F6TM250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25F6TM250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25F6TM250 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D provides L (thermal) overload protection and I (magnetic) short-circuit protection — a fixed-trip curve suited for distribution feeders where coordination with downstream breakers is set by the magnetic pickup. The 4-pole version (4P) with neutral on the left and no earth-leakage module (without Vigi) is a straight distribution breaker; if you need ground-fault protection, you add an external Vigi module or swap to a Micrologic electronic trip. Breaking capacity is the headline: 85 kA Icu at 240 V AC, 36 kA Icu at 415 V AC, and 35 kA at 480 V AC (UL 60947-4-1). The F breaking-capacity code (36 kA at 415 V) means this breaker clears faults up to 36 kA symmetrical without welding or rupturing — sufficient for most industrial distribution boards with a transformer of 1–2 MVA. The toggle handle gives positive indication of contact position. Mounts on a backplate (not DIN rail) — allow 140 mm width, 161 mm height, 86 mm depth for enclosure sizing.

Integration notes

Front connections top and bottom simplify busbar or cable routing in a panel. Five accessory slots allow adding auxiliary contacts, shunt trips, or undervoltage releases without removing the breaker. IP40 front face, IK07 impact resistance — suitable for a lockable distribution board but not washdown environments. Operating altitude 0–2000 m without derating; above 2000 m up to 5000 m requires derating per the manufacturer's table. Electrical durability: 20,000 cycles at 440 V In/2, 10,000 cycles at 440 V In — adequate for a distribution breaker that sees infrequent switching; not rated for motor-starting duty (utilisation category A, not AC-3).

Frequently asked questions

What is the breaking capacity of C25F6TM250 at 415 V?

The C25F6TM250 has a breaking capacity of 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, and 35 kA Icu at 480 V AC conforming to UL 60947-4-1.

What compliance documentation does C25F6TM250 carry?

The C25F6TM250 is certified to EN/IEC 60947-2 and UL 60947-4-1 standards. It is rated for isolation per EN/IEC 60947-2, with pollution degree 3 per IEC 60664-1 and overvoltage category III. Specific RoHS/REACH declarations are provided by Schneider Electric on request.

Where can I buy C25F6TM250 and how is it quoted?

The C25F6TM250 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time. For volume purchases, the 250 A frame is a common BOM line with generally predictable lead times.

MPN
C25F6TM250