Skip to main content
Schneider Electric C25F6TM250C — Miniature Circuit Breakers (MCB)

Schneider Electric C25F6TM250C ComPacT NSX250F, 250A, 36kA 4

MPNC25F6TM250C
Active

Schneider Electric ComPacT NSX NSX250F, circuit breaker, 250 A, 4P, TM-D trip unit, 36 kA Icu at 415 V AC, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25F6TM250C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25F6TM250C — Ratings
ParameterValue
Rated current (In)250 A at 50 °C
Poles configuration4P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25F6TM250C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25F6TM250C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C25F6TM250C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25F6TM250C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25F6TM250C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Mounts on a backplate, accepts front-front wiring, and occupies a 140 mm wide footprint with 35 mm connection pitch. IK07 impact rating means it survives a 2 J hammer strike during installation.

Durability and application context

Rated for 20,000 mechanical cycles and 20,000 electrical cycles at 440 V In/2 — enough for frequent switching in distribution panels feeding motor control centres or lighting circuits. At full rated current (440 V In) it still delivers 10,000 electrical cycles, which aligns with a 10–15 year service life in a typical industrial environment. The TM-D trip unit is field-replaceable, so you can swap the thermal-magnetic element without pulling the breaker from the backplate.

Frequently asked questions

What is the breaking capacity of C25F6TM250C at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, which is the F breaking capacity code. At 220/240 V it rises to 85 kA.

MPN
C25F6TM250C