Skip to main content
Schneider Electric C25V42D250 — Miniature Circuit Breakers (MCB)

Schneider Electric C25V42D250 ComPacT NSX250HB1, 250 A, 85 k

MPNC25V42D250
Active

Schneider Electric ComPacT NSX, NSX250HB1, circuit breaker, 250 A at 40 °C, 85 kA Icu at 500 V AC, MicroLogic 2.2 electronic trip unit, 4 poles.

$11.41Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25V42D250 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25V42D250 — Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25V42D250 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25V42D250 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25V42D250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25V42D250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25V42D250 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range100...250 A
Trip unit protection functionsLSoI

Product details

What it is and what it does

The Schneider Electric C25V42D250 is a ComPacT NSX250HB1 molded-case circuit breaker, 4-pole, rated 250 A at 40 °C with an electronic MicroLogic 2.2 trip unit. It's built to EN/IEC 60947-2, so it's certified for distribution and motor-circuit protection in industrial panels. The 85 kA Icu at 500 V AC means it can safely interrupt a fault up to that level without cascading upstream — that's the number that decides whether it holds coordination in a high-fault installation.

What the ratings mean for fit

The MicroLogic 2.2 gives you L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous) protection curves — all adjustable via the trip unit dials. That electronic trip means you get thermal memory that holds for 20 minutes before and after tripping, so a reclose after a hot overload won't let the conductor overheat on the second hit. The 250 A frame is the continuous rating at 40 °C; if your panel ambient runs hotter, you'll need to derate per the manufacturer's curve. Breaking capacity is 85 kA Icu at 500 V AC, 80 kA at 525 V, and 75 kA at 690 V — that's a high-interrupting rating for a 250 A frame, so it handles most industrial service-entrance or sub-feed applications without needing a current-limiting fuse upstream.

Where it goes and how it mounts

Mounts on a backplate — horizontal or vertical, flat on the back — so it's a panel-mount breaker, not a DIN-rail snap-on. The 140 mm width and 161 mm height fit standard ComPacT NSX cutouts. Front connections both top and bottom, neutral on the left. IP40 front face (IK07 impact) means it's fine inside a clean enclosure but not for washdown. Pollution degree 3 per IEC 60664-1 — that's conductive pollution, typical of industrial environments where the panel isn't sealed.

Frequently asked questions

What is the breaking capacity of C25V42D250?

85 kA Icu at 500 V AC, 80 kA at 525 V AC, and 75 kA at 660/690 V AC, all per IEC 60947-2.

What trip unit does C25V42D250 use?

It uses an electronic MicroLogic 2.2 trip unit with L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous) protection.

Where can I buy C25V42D250?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
C25V42D250