Skip to main content
Schneider Electric C25W42D100 — Miniature Circuit Breakers (MCB)

Schneider C25W42D100 ComPacT NSX 100A 4P Circuit Breaker, 10

MPNC25W42D100
Active

Schneider Electric ComPacT NSX series, C25W42D100, 4P 100 A MCCB with MicroLogic 2.2 electronic trip unit, 100 kA Icu at 690 V AC, backplate mount.

$11.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25W42D100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25W42D100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25W42D100 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25W42D100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25W42D100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25W42D100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25W42D100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range40...100 A
Trip unit protection functionsLSoI

Product details

The C25W42D100 is a Schneider ComPacT NSX moulded-case circuit breaker, 4-pole, rated 100 A at 40 °C with a MicroLogic 2.2 electronic trip unit. The 100 kA Icu at 690 V AC (also rated 100 kA at 500 V and 525 V) means it can interrupt a fault current up to that level without failing — essential for high-fault-capacity distribution boards where upstream transformers can deliver tens of kiloamps into a bolted short. The electronic trip gives you LSI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I). The 20-minute thermal memory before and after tripping means the breaker remembers prior heating, so it won't reclose into a still-hot conductor and nuisance-trip again — useful on motor or transformer feeders that draw high inrush.

Mounts on a backplate — no DIN rail here. The 35 mm connection pitch and front-facing connections (both upside and downside) keep wiring accessible. It sits in any orientation: horizontal, vertical, or flat on the back. IP40 front face keeps out tools and fingers; IK07 impact rating means it survives a 2 J knock during panel assembly.

Utilisation category A (no intentional short-time delay for selectivity with downstream breakers — the So protection provides a fixed short-time delay within the breaker itself). Electrical durability: 20,000 cycles at 440 V In/2, 10,000 at 440 V In, 10,000 at 690 V In/2, 5,000 at 690 V In. Mechanical durability: 20,000 cycles. Neutral on the left, toggle control, 50/60 Hz network. Operating altitude 0–2000 m without derating, 2000–5000 m with derating.

Frequently asked questions

Where can I buy C25W42D100 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is C25W42D100's breaking capacity?

100 kA Icu at 500 V, 525 V, and 660/690 V AC 50/60 Hz conforming to IEC 60947-2 — the HB2 code indicates the 100 kA at 690 V rating.

What trip unit does C25W42D100 use?

A MicroLogic 2.2 electronic trip unit rated 100 A at 40 °C, providing LSI protection (long-time overload, short-time short-circuit with fixed delay, instantaneous short-circuit).

MPN