Skip to main content
Schneider Electric C25W45E100 — Miniature Circuit Breakers (MCB)

C25W45E100 ComPacT NSX 100A, 100kA at 690V, MicroLogic 5.2 E

MPNC25W45E100
Active

Schneider Electric ComPacT NSX, 100 A, 100 kA Icu at 690 V AC, 4P, MicroLogic 5.2 E electronic trip unit with energy metering, toggle control, LCD display.

$1,427.41Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25W45E100 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25W45E100 — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25W45E100 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25W45E100 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25W45E100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25W45E100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25W45E100 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range40...100 A
Trip unit protection functionsLSI

Product details

ComPacT NSX with MicroLogic 5.2 E — 100 A, 100 kA at 690 V

The C25W45E100 is a Schneider Electric ComPacT NSX molded-case circuit breaker in the 4-pole (4P) form factor, fitted with a MicroLogic 5.2 E electronic trip unit. Rated 100 A at 40 °C, it delivers a full-rated 100 kA Icu breaking capacity at 690 V AC 50/60 Hz per IEC 60947-2 — meaning it can safely interrupt fault currents up to that level without upstream cascading, even on 690 V industrial mains. The 'E' designation in the trip unit adds integrated energy metering: real-time power, demand current, power quality, and time-stamped event logs accessible via the front LCD display.

The 100 kA Icu at 690 V AC is the headline figure — this breaker handles high-fault industrial environments where standard 36 kA or 50 kA units would fail. That matters for motor or transformer feeders where repeated inrush can nuisance-trip a thermal-magnetic breaker. The integrated energy meter eliminates a separate panel meter on distribution boards where per-circuit energy monitoring is required.

Integration notes

Front connections both upside and downside. Toggle control with LCD display for local status and energy data. IK07 impact resistance covers accidental tool strikes during panel maintenance.

Frequently asked questions

What is the breaking capacity of C25W45E100 at 690 V?

100 kA Icu at 660/690 V AC 50/60 Hz per IEC 60947-2. It also delivers 100 kA Icu at 500 V and 525 V AC.

Where can I buy C25W45E100 and get a price?

Sourced to order against an RFQ through independent distribution. Submit a quote request for current pricing and availability — confirmed at time of quote.

What compliance documentation does C25W45E100 carry?

Designed to EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, and IK07 impact per IEC 62262. The MicroLogic 5.2 E trip unit is electronic, not thermal-magnetic.

MPN