Skip to main content
Schneider Electric C25W46E250 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C25W46E250 ComPacT NSX 250A, 100kA 690V

MPNC25W46E250
Active

Schneider Electric ComPacT NSX, NSX250HB2, 4P, 250 A, MicroLogic 6.2 E electronic trip unit, 100 kA Icu at 690 V AC, toggle control, LCD display.

$13.63Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25W46E250 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C25W46E250 — Electrical Ratings
ParameterValue
Rated current (In)250 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C25W46E250 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX250HB2
C25W46E250 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C25W46E250 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C25W46E250 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

250 A MCCB with ground-fault trip — MicroLogic 6.2 E

The Schneider Electric C25W46E250 is a ComPacT NSX250HB2 molded case circuit breaker with a 250 A frame at 40 °C, fitted with a MicroLogic 6.2 E electronic trip unit. This is a 4-pole unit with front-connect terminals, rated for distribution duty per EN/IEC 60947-2. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground-fault) protection — the G function is the distinguishing feature here, making this breaker suitable for systems where ground-fault coordination is required, such as on IT or TN-S networks with sensitive earth-leakage detection.

Rated 100 kA Icu at 500 V AC, 525 V AC, and 660/690 V AC (50/60 Hz) per IEC 60947-2. That is a consistent high-interrupting rating across the voltage band — not a derated figure at the top end. For a site electrical engineer coordinating a distribution board, this HB2 (100 kA at 690 V) grade means the breaker can be placed upstream of lower-rated devices without exceeding its short-circuit withstand. The utilisation category is A, so it is not intended for reverse-feed or bidirectional current flow applications without manufacturer guidance.

Mounts on a backplate (not DIN rail) — the 161 mm height, 140 mm width, and 86 mm depth fit standard ComPacT NSX cutouts. Neutral is on the left.

Durability and metering capability

Mechanical durability is 20,000 cycles; electrical durability is 20,000 cycles at 440 V at half-rated current, 10,000 cycles at full 440 V, and 5,000 cycles at 690 V full load. The MicroLogic 6.2 E includes an energy meter function and communicates time-stamped event histories, maintenance indicators, power quality data, and demand values — useful for a facility engineer tracking load profiles without a separate power meter.

Frequently asked questions

What is the breaking capacity of C25W46E250?

Rated 100 kA Icu at 500 V AC, 525 V AC, and 660/690 V AC (50/60 Hz) per IEC 60947-2. The breaking capacity code is HB2.

What protection functions does the MicroLogic 6.2 E trip unit provide?

L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground-fault) protection. The G function is the key differentiator for ground-fault coordination.

Where can I buy C25W46E250 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation is available for C25W46E250?

The breaker is certified to EN/IEC 60947-2. Pollution degree 3 per IEC 60664-1. The manufacturer provides standard compliance documentation; specific RoHS/REACH/UL declarations should be requested at quote time.