Schneider Electric CAD326SLS207 — Contactors

Schneider CAD326SLS207 TeSys Deca S207 Control Relay, 3NO+2N

MPNCAD326SLS207
Active

Schneider Electric TeSys Deca S207 railway control relay, CAD326SLS207, 3NO+2NC, <=690V, 72V DC low consumption coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

CAD326SLS207 — Identification
ParameterValue
Product / component typeControl relay
Series / rangeTeSys
ApplicationControl circuit
CAD326SLS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)10 MOhm
Utilisation categoryAC-14 DC-13 AC-15
CAD326SLS207 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude0...3000 m
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV0 conforming to UL 94
CAD326SLS207 — Approvals
ParameterValue
StandardsEN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
CAD326SLS207 — Mechanical
ParameterValue
Width45 mm
Height77 mm
Depth93 mm

Product details

Integration notes

The relay occupies a 45 mm wide footprint on the DIN rail, 93 mm deep, 77 mm tall. The low-consumption 72 V DC coil reduces heat load in a crowded cabinet. Operating temperature range is -40 to 70 °C, storage -60 to 80 °C, and it works at altitudes up to 3000 m — suitable for unpressurised railcar compartments or high-altitude installations.

Frequently asked questions

What standards does CAD326SLS207 comply with?

It complies with EN 45545 R22 HL3 (railway fire safety), EN/IEC 60947-4-1 and 60947-5-1 (industrial control), UL 60947-4-1, and CSA C22.2 No 60947-4-1. Fire resistance is 850 °C per IEC 60695-2-1, flame retardance V0 per UL 94.

What is the closest pin-compatible alternative in the TeSys family?

The TeSys Deca range includes other control relays with the same 45 mm width and similar pole configurations, but pin compatibility depends on the specific coil voltage and utilisation category. Check the coil voltage and contact ratings against your circuit; the CAD326SLS207 is the railway-grade variant with EN 45545 compliance.

What is the depth of CAD326SLS207?

The depth is 93 mm.

What compliance documentation is available for CAD326SLS207?

The manufacturer provides RoHS, REACH, UL, and IEC compliance declarations. Request the documentation package with your RFQ.

MPN
CAD326SLS207