Skip to main content
Schneider Electric EZC250H4100 — Circuit Breaker Accessories

Schneider Electric EZC250H4100 EasyPact EZC250H, 100 A, 4P,

MPNEZC250H4100
Obsolete

Schneider Electric EasyPact EZC250H, molded case circuit breaker, 4 poles, 100 A, TM-D thermal-magnetic trip unit, H breaking capacity, 25 kA Icu at 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC250H4100 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H4100 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]100 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250H4100 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H4100 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250H4100 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H4100 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2

Product details

The Schneider Electric EZC250H4100 is a 4-pole molded case circuit breaker from the EasyPact EZC250H series, rated 100 A at 40 °C with a TM-D thermal-magnetic trip unit. With IP20 finger-safe terminals and IK07 impact resistance, it mounts on a backplate with fixed front connections, making it a straightforward swap into an existing EasyPact footprint.

Breaking capacity — what the H rating means for your panel

The H suffix on EZC250H4100 defines the interrupting range: 85 kA Icu at 220–240 V AC, 36 kA at 380–415 V, 25 kA at 440 V, and 10 kA at 550 V AC. For DC circuits, it handles 30 kA at 125 V DC (1-pole) and 30 kA at 250 V DC (2-pole). This spread lets you coordinate selectivity downstream of a higher-rated main without oversizing the branch breaker.

Fixed mounting on a backplate, front connections both line and load sides. The toggle handle provides positive contact indication — you see the mechanical state independent of the trip mechanism.

Designed and tested to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. The breaker is certified for isolation per IEC 60947-2, meaning you can safely use it as a disconnecting means with visible gap. Rated insulation voltage 690 V AC, operational voltage 550 V AC or 250 V DC. No integrated earth-leakage protection; the TM-D trip handles short-circuit and overload only.

Frequently asked questions

What is the breaking capacity of the EZC250H4100 at 440 V?

The EZC250H4100 delivers 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2. This is the H breaking capacity code rating.

Does the EZC250H4100 include earth-leakage protection?

No, this breaker is supplied without earth-leakage protection. The TM-D trip unit provides only short-circuit and overload protection.

Where can I buy the EZC250H4100 and how is it quoted?

The EZC250H4100 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN