Skip to main content
Schneider Electric EZC630H4600N — Circuit Breaker Accessories

Schneider Electric EZC630H4600N EasyPact EZC630H, 630 A, 4P,

MPNEZC630H4600N
Obsolete

Schneider Electric EasyPact EZC630H, EZC630H4600N, molded case circuit breaker, 630 A, 4 poles, 50 kA Icu at 380 V AC, thermal-magnetic TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC630H4600N — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC630H4600N — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]630 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC630H4600N — Protection & Performance
ParameterValue
Breaking capacity50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating600 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Electrical durabilityCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Local signallingPositive contact indication
Contact position indicatorYes
EZC630H4600N — Mechanical
ParameterValue
Connection pitch45 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC630H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width185 mm
Height255 mm
Depth140 mm
ColourBlack
EZC630H4600N — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC630H4600N — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EZC630H4600N is a 4-pole molded case circuit breaker from the EasyPact EZC630H series, rated 630 A at 40 °C and 600 A at 50 °C. The TM-D thermal-magnetic trip unit provides overload and short-circuit protection, with a fixed magnetic tripping threshold of 4000 A. The 70 kA Icu at 220/230 V AC gives additional headroom on lower-voltage distribution. This is a Category A circuit breaker (no intentional short-time delay), suited for distribution applications where selectivity is achieved by current grading rather than time delay. The IP20 finger-safe enclosure and IK07 impact resistance are standard for panel-mounted MCCBs — it's designed for fixed backplate mounting with front-front connections (both line and load sides connect from the front).

Compliance documentation covers JIS C8201-2-2, EN/IEC 60947-2, and GB/T 14048.2. The breaker is certified for isolation per IEC 60947-2, and the positive contact indication gives a visual confirmation of contact position.

Mounts on a backplate with a fixed mounting mode — no DIN rail adapter. The 185 mm width, 255 mm height, and 140 mm depth fit standard distribution panel cutouts; the 45 mm pole pitch is consistent with other EasyPact EZC frames. Front-front connections simplify busbar routing in switchboards, and the toggle control provides a clear on/off/ tripped position. The 4000 A magnetic trip point is fixed — no adjustment. For selectivity studies, the electrical endurance is 3000 cycles at 415 V AC (Category A), and mechanical endurance is 10,000 cycles. The breaker ships as a single piece, without earth-leakage protection module (add external RCD if needed).

Frequently asked questions

How do I get pricing and availability for EZC630H4600N?

Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront; the part is sourced to order through independent distribution channels.

What are the key ratings of the EZC630H4600N?

Rated 630 A at 40 °C (600 A at 50 °C), 4 poles, breaking capacity 50 kA Icu at 380/400/415/440 V AC, 70 kA Icu at 220/230 V AC. Thermal-magnetic TM-D trip unit with fixed magnetic trip at 4000 A.

What compliance documentation does Schneider provide for EZC630H4600N?

The breaker complies with JIS C8201-2-2, EN/IEC 60947-2, and GB/T 14048.2. It is certified for isolation per IEC 60947-2 and rated Pollution Degree 3.

MPN