Schneider Electric EZC630H44600N

Schneider Electric EZC630H44600N EasyPact EZC630H, 630 A, 4P

MPN EZC630H44600N
Obsolete

Schneider Electric EasyPact EZC630H, circuit breaker, EZC630H44600N, 630 A at 40 °C, 4 poles, TM-D thermal-magnetic trip unit, 50 kA Icu at 380-440 V AC, fixed mounting, front connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC630H44600N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC630H44600N additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC630H44600N is a 4-pole EasyPact EZC630H moulded-case circuit breaker rated 630 A at 40 °C ambient — the current you spec for the main feeder or large motor branch, not a subfeed. The TM-D thermal-magnetic trip unit gives fixed overload and short-circuit protection curves; no interchangeable rating plugs or electronic adjustments here, so the 630 A frame is the trip rating, not just a frame size you can down-rate. That simplifies BOM but means you commit to the full 630 A or drop to a smaller frame. Breaking capacity is 50 kA Icu at 380/400/415/440 V AC (50/60 Hz) per IEC 60947-2, and 70 kA Icu at 220/230 V AC. For a 630 A distribution breaker on a 400 V industrial panel, 50 kA Icu gives solid headroom over typical utility fault levels (usually 25–35 kA at the service entrance). The H breaking capacity code in EZC630H signals this is the high-interrupting variant of the EZC630 family. For frequent switching duty, add a contactor downstream.

Deployment context

Fixed mounting on a backplate with front-front connections — line and load cables both terminate on the front face. The 185 mm width, 255 mm height, and 140 mm depth require clearance for 630 A conductors. IP20 finger-safe protection on the front and IK07 impact resistance cover normal panel installation. This is not a washdown-rated enclosure — keep it inside a cabinet rated IP54 or better if the environment is wet or dusty.

Standards compliance covers GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-1, and EN/IEC 60947-2. No UL or CSA listing is stated in the evidence. Toggle control with positive contact indication gives a visible break confirmation — the handle position shows the contact state even if the mechanism fails internally. That is a useful diagnostic cue for field service techs isolating a faulted feeder: you see the handle in the OFF or tripped position and know the contacts have opened.

MPN