Schneider Electric EZC630H4630N — Circuit Breaker Accessories

Schneider Electric EZC630H4630N EasyPact EZC630H 630A 4P MCC

MPNEZC630H4630N
Active

Schneider Electric EasyPact EZC630H, MCCB, 630 A, 4P, thermal-magnetic trip unit TM-D, 50 kA Icu at 440 V AC, IP20, black.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC630H4630N — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC630H4630N — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]630 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC630H4630N — Protection & Performance
ParameterValue
Breaking capacity50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating630 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Electrical durabilityCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Local signallingPositive contact indication
Contact position indicatorYes
EZC630H4630N — Mechanical
ParameterValue
Connection pitch45 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC630H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width185 mm
Height255 mm
Depth140 mm
ColourBlack
EZC630H4630N — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC630H4630N — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

It breaks 50 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, enough for most distribution panels feeding motor control centres or heavy plant loads. Four poles, no neutral protection — the fourth pole is switched only, no integral ground-fault module. Mechanical durability is 10,000 cycles, electrical 3,000 at 415 V, which is typical for a fixed-mount distribution breaker that sees infrequent switching.

Fixed backplate mount, front-front connection — both line and load lugs are accessible from the front, so you can land cable without reaching behind the panel. Dimensions are 255 mm high, 185 mm wide, 140 mm deep. The 45 mm pole pitch is standard for this class; a 4P breaker occupies roughly 180 mm of backplate width. IP20 finger-safe terminals, IK07 impact rating — tough enough for a general-purpose enclosure but not for a washdown zone.

Frequently asked questions

What is the breaking capacity of EZC630H4630N at 440 V?

It is rated 50 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, and 70 kA Icu at 220/230 V AC.

Where can I buy EZC630H4630N?

We source this breaker to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What compliance documentation does this brand provide for EZC630H4630N?

The breaker is certified to EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries IP20 and IK07 ratings per IEC 60529 and EN 50102 respectively.

MPN
EZC630H4630N