Skip to main content
Schneider Electric EZC630N3630N — Circuit Breaker Accessories

Schneider Electric EZC630N3630N EasyPact EZC630N, 630A, 36kA

MPNEZC630N3630N
Active

Schneider Electric EasyPact EZC630N, molded case circuit breaker, 3P, 630 A, 36 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, fixed mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC630N3630N — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC630N3630N — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]630 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC630N3630N — Protection & Performance
ParameterValue
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating630 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Electrical durabilityCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Local signallingPositive contact indication
Contact position indicatorYes
EZC630N3630N — Mechanical
ParameterValue
Connection pitch45 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC630N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width185 mm
Height255 mm
Depth140 mm
ColourBlack
EZC630N3630N — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC630N3630N — Approvals
ParameterValue
StandardsEN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1

Product details

The Schneider Electric EZC630N3630N is an EasyPact EZC630N molded case circuit breaker (MCCB) rated 630 A at 40 °C, with the TM-D thermal-magnetic trip unit rated 630 A at 50 °C. The 36 kA Icu at 440 V AC (40 kA at 220/230 V) is the interrupting capacity: it can safely clear a fault up to that level without welding contacts or rupturing the case. Below that, it still interrupts; above it, the upstream device needs to clear the fault first. The magnetic trip is fixed at 5000 A — that's the instantaneous pickup for short-circuit protection, not adjustable on the TM-D unit. The breaker is Category A (no intentional short-time delay), meaning it's intended for distribution where selectivity is achieved by current magnitude and impedance, not by time grading.

Deployment context

Fixed-mount, backplate installation — no DIN-rail adapter on this frame. Front-front connection (line and load both front-accessible) makes it straightforward for panel builders: bus bars or cable lugs land on the same face. The 45 mm pole pitch matches standard busbar spacing for 3-pole MCCBs in distribution boards. IP20 finger-safe terminals; IK07 impact resistance means it handles incidental tool strikes during panel assembly. No earth-leakage protection built in; if you need ground-fault on this feeder, add an external Vigi module or upstream RCD.

Frequently asked questions

What is the breaking capacity of EZC630N3630N at 440 V?

36 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 220/230 V it's 40 kA Icu.

Where can I buy the EZC630N3630N and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm line.

What standards does this breaker comply with?

EN/IEC 60947-2, GB/T 14048.2, JIS C8201-2-2, and EN/IEC 60947-1. Suitable for isolation per IEC 60947-2.

What is the trip unit type on EZC630N3630N?

TM-D thermal-magnetic, fixed at 630 A at 50 °C. Magnetic pickup is fixed at 5000 A — no adjustment on this unit.

MPN
EZC630N3630N