EZC630N4400N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch44 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC630N4400N additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC630N4400N is a 4-pole EasyPact EZC630N circuit breaker rated 630 A at 40 °C with a TM-D thermal-magnetic trip unit. It is marked Category A, meaning it is not intended for selective coordination with other breakers in series — plan for full discrimination upstream if needed.

Deployment context

This breaker mounts fixed to a backplate with front-front connections — no DIN-rail clip, so panel layout needs dedicated mounting holes and busbar takeoffs. The 185 mm width and 255 mm height determine the cutout and enclosure fill factor. IP20 means finger-safe but not washdown; install inside a locked panel. IK07 gives basic impact resistance for the enclosure face.