Schneider Electric EZCV250H4100 — Circuit Breaker Accessories

Schneider Electric EZCV250H4100 EasyPact EZCV250H MCCB, 100

MPNEZCV250H4100
Obsolete

Schneider Electric EasyPact EZCV250H series, molded case circuit breaker, 4 poles, 100 A at 40 °C, breaking capacity 100 kA Icu at 240 V AC, thermal-magnetic TM-D trip unit with earth-leakage protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZCV250H4100 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZCV250H4100 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]100 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZCV250H4100 — Protection & Performance
ParameterValue
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 40 °C
Trip unit nameTM-D
Protection typeOverload protection Earth-leakage protection Short-circuit protection
Earth-leakage protectionWith
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZCV250H4100 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZCV250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth68 mm
EZCV250H4100 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZCV250H4100 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2

Product details

The Schneider Electric EZCV250H4100 is a 4-pole molded case circuit breaker from the EasyPact EZCV250H series, rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit and integral earth-leakage protection. Its breaking capacity reaches 100 kA Icu at 220–240 V AC, 36 kA at 380–415 V, and 25 kA at 440 V, all per IEC 60947-2. This places it in the H (high) breaking capacity class, suitable for distribution panels where fault levels are substantial.

For higher ambient temperatures (up to 70 °C per the operating range), derating applies — the datasheet curve governs the actual limit. The TM-D trip unit provides thermal overload protection (inverse-time) and magnetic short-circuit protection (fixed instantaneous threshold), so it suits general distribution and feeder circuits where coordination with downstream devices is needed. At 440 V the rating drops to 25 kA, reflecting the higher arc energy. Earth-leakage protection is integrated, so no external RCCB or RCBO is needed for ground-fault detection on the outgoing circuit. The protected poles are 3t (three poles with thermal-magnetic protection, one pole switched only), and neutral protection is not provided — the neutral pole is a switched pole without a trip element. This is typical for 3-phase + N distribution where the neutral is not overloaded.

Pollution degree 3 (industrial environment with conductive pollution) is the rated condition.