Skip to main content
Schneider Electric EZCV250H4160 — Circuit Breaker Accessories

Schneider Electric EZCV250H4160 EasyPact EZCV250H, 160 A, 4P

MPNEZCV250H4160
Obsolete

Schneider Electric EasyPact EZCV250H, molded case circuit breaker, 160 A, 4P, TM-D thermal-magnetic trip, 100 kA Icu at 240 V AC, earth-leakage protection, IP20, IK07.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZCV250H4160 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZCV250H4160 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]160 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZCV250H4160 — Protection & Performance
ParameterValue
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating160 A at 40 °C
Trip unit nameTM-D
Protection typeOverload protection Earth-leakage protection Short-circuit protection
Earth-leakage protectionWith
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZCV250H4160 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZCV250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth68 mm
EZCV250H4160 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZCV250H4160 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EZCV250H4160 is a 4-pole molded case circuit breaker from the EasyPact EZCV250H series, rated 160 A at 40 °C with a thermal-magnetic TM-D trip unit. It is designed for distribution applications and carries a 100 kA Icu breaking capacity at 220...240 V AC, 25 kA Icu at 440 V AC, and 36 kA Icu at 380...415 V AC — all conforming to IEC 60947-2. The breaker includes integral earth-leakage protection, making it suitable for systems where ground-fault detection is required without a separate add-on module.

The TM-D trip unit provides thermal overload protection (inverse-time) and magnetic short-circuit protection (fixed instantaneous).

Fixed backplate mounting with front-front connections (both line and load sides terminate at the front). The 35 mm connection pitch matches standard busbar and cable lug spacing. IP20 finger-safe protection on the front face; IK07 impact resistance for panel environments.

Frequently asked questions

What is the breaking capacity of the EZCV250H4160 at different voltages?

The breaker has a 100 kA Icu at 220...240 V AC, 36 kA Icu at 380...415 V AC, and 25 kA Icu at 440 V AC, all conforming to IEC 60947-2.

Does the EZCV250H4160 include earth-leakage protection?

Yes, it includes integral earth-leakage protection, so no separate add-on module is needed for ground-fault detection.

Where can I buy the EZCV250H4160 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

MPN
EZCV250H4160