Schneider Electric G12T4F50 — Miniature Circuit Breakers (MCB)

Schneider Electric G12T4F50 GoPact MCCB 125, 50 A, 10 kA, 4P

MPNG12T4F50
Active

Schneider Electric GoPact MCCB 125, circuit breaker, 4P, 50 A, TM-D trip unit, 10 kA at 415 V AC, IP20, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12T4F50 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12T4F50 — Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12T4F50 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12T4F50 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12T4F50 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12T4F50 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12T4F50 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12T4F50 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric G12T4F50 is a GoPact MCCB 125 molded case circuit breaker rated 50 A at 40 °C with a TM-D thermal-magnetic trip unit. Its 10 kA breaking capacity at 415 V AC (performance level T) suits it for distribution panels where fault levels stay under that threshold — common in commercial and light industrial installations. The 4-pole configuration with neutral protection set at 1 x Ir (4D) covers all live conductors, including the neutral as a protected pole.

Ratings and what they mean for your panel

The 50 A continuous rating at 40 °C is the current the breaker carries without tripping under normal conditions. If your panel ambient runs hotter, expect derating — the trip unit is calibrated to this baseline. The 10 kA breaking capacity at 415 V AC means it can safely interrupt a fault current up to that level without welding contacts or cascading failure upstream; verify your available fault current at the panelboard stays under this value during coordination study. The TM-D trip unit provides LI protection: thermal (L) for overload with a time-delay characteristic, and magnetic (I) for short-circuit with instantaneous response. This is the standard protection profile for distribution feeders and branch circuits where motor inrush is not a concern — the magnetic pickup is fixed and not adjustable, so confirm it coordinates with downstream devices. Rated insulation voltage (Ui) is 440 V AC, and operational voltage (Ue) is 415 V AC, 50/60 Hz. The breaker is suitable for isolation per EN/IEC 60947-2, meaning you can use it as a visible-break disconnect for safe maintenance — provided the toggle position is verified.

Mounting and integration

Mounts fixed to a backplate — not DIN-rail — via screw terminals with a 25 mm connection pitch. Accepts horizontal or vertical orientation, flat on the back. The IP20 finger-safe enclosure protects against accidental contact but is not rated for washdown or outdoor exposure; install inside a panel rated for the environment. Front-facing connections on both line and load sides simplify bus-bar and cable routing in a standard distribution panel. The grey (RAL 7035) housing blends with common enclosure interiors. Pollution degree 3 per IEC 60664-1 and overvoltage category III mean it is designed for fixed installations where transient overvoltages are controlled — typical in building distribution boards, not exposed substations.

Frequently asked questions

What is the G12T4F50 used for?

It is a 4-pole molded case circuit breaker rated 50 A with a 10 kA breaking capacity at 415 V AC, used for overload and short-circuit protection in distribution panels in commercial and light industrial installations.

Where can I buy the G12T4F50?

Sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

What standards does the G12T4F50 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H, and is suitable for isolation per EN/IEC 60947-2.

MPN
G12T4F50