Skip to main content
Schneider Electric GV7RS20 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV7RS20 Motor Circuit Breaker, 3P, 50 kA

MPNGV7RS20
Obsolete

Schneider Electric TeSys GV7RS20 motor circuit breaker, 3-pole, thermal-magnetic trip unit, AC-3 rated, 50 kA breaking capacity at 500 V AC, IP40 with terminal shrouds.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV7RS20 — Identification
ParameterValue
Product nameTeSys GV7
Product rangeTeSys
Product/component typeCircuit breaker
Device applicationMotor
GV7RS20 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 65 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 70 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 10 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz IEC 60947-2
Rated insulation voltage (Ui)750 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz IEC 60947-4-1
Utilisation categoryAC-3 IEC 60947-4-1
GV7RS20 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes IEC 60947-1
Electrical durability (cycles)30000 cycles AC-3 440 V In 50000 cycles AC-3 440 V In/2
Mechanical durability (cycles)50000 cycles
GV7RS20 — Mechanical
ParameterValue
Mounting supportFlush Panel mounting Rail Kit for fixing the switchgear
Mounting modeBy screws By clips
Control typeRocker lever
Terminal connection typeBars Cable with lug - external diameter: 0.4 in (10 mm) Screw Bare cable connectors 0.002...0.1 in² (1.5...95 mm²)
Terminal tightening torque88.5 lbf.in (10 N.m) screw M6 132.8 lbf.in (15 N.m) bare cable connectors 0.002...0.1 in² (1.5...95 mm²)
Width4.1 in (105 mm)
Height6.3 in (161 mm)
Depth4.4 in (111 mm)
GV7RS20 — Environmental
ParameterValue
Operating ambient temperature-13...158 °F (-25...70 °C)
Storage ambient temperature-67...203 °F (-55...95 °C)
IP degree of protectionIP40 IEC 60529 with terminal shrouds)
Pollution degree3
GV7RS20 — Approvals
ParameterValue
StandardsNF C 63-120 NF C 79-130 NF C 63-650 EN/IEC 60947-4-1 EN/IEC 60947-2 VDE 0660 EN/IEC 60947-1 VDE 0113
GV7RS20 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 220/240 V AC 50/60 Hz IEC 60947-2 100 % 380/415 V AC 50/60 Hz IEC 60947-2 100 % 660/690 V AC 50/60 Hz IEC 60947-2

Product details

Motor circuit breaker for AC-3 duty

The GV7RS20 is a 3-pole thermal-magnetic motor circuit breaker from the Schneider TeSys GV7 range, designed for AC-3 switching duty under IEC 60947-4-1. The thermal-magnetic trip unit combines a bimetallic overload element with a magnetic short-circuit release, giving phase-failure sensitivity per IEC 60947-4-1 § 7-2-1-5-2. This means the breaker will trip if one phase drops out, preventing single-phasing damage to the motor.

Breaking capacity across voltage levels

At 440 V AC it delivers 65 kA. The continuous duty rating per IEC 60947-4-1 means the breaker carries rated current indefinitely without tripping from thermal buildup. Electrical durability is 30,000 cycles at AC-3 440 V at full rated current, and 50,000 cycles at half current. Mechanical durability is 50,000 cycles.

Panel mounting and enclosure fit

The dimensions are 161 mm height, 105 mm width, and 111 mm depth. Connection pitch is 35 mm without spreaders or 45 mm with spreaders, which matters when ganging multiple breakers side-by-side in a panel. IP40 protection with terminal shrouds (IEC 60529) suits indoor panel installation. The pollution degree 3 rating means it tolerates conductive pollution in industrial environments. Operating altitude is limited to 2000 m without derating.

Standards compliance includes EN/IEC 60947-4-1, EN/IEC 60947-2, VDE 0660, NF C 63-120, and NF C 79-130. The breaker is suitable for isolation per IEC 60947-1, meaning it can be used as a visible disconnect point in the motor circuit.

Frequently asked questions

What is the breaking capacity of GV7RS20 at 480 V?

The breaking capacity (Icu) at 440 V AC is 65 kA, and at 500 V AC it is 50 kA. For a 480 V system, the 50 kA rating at 500 V applies as the conservative figure.

MPN
GV7RS20