Skip to main content
Schneider Electric LC1F500VD — Contactors

Schneider Electric LC1F500VD TeSys F Contactor, 700 A AC-3,

MPNLC1F500VD
Obsolete

Schneider Electric TeSys F LC1F500VD, 3-pole contactor, 700 A AC-3 rated operational current, 400 VDC control circuit, 250 kW motor power at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1F500VD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1F500VD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-3 AC-4 AC-1
LC1F500VD — Contacts & Poles
ParameterValue
Pole configuration3P
LC1F500VD — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F500VD — Approvals
ParameterValue
StandardsEN 60947-4-1 IEC 60947-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1
LC1F500VD — Mechanical
ParameterValue
Width233 mm
Height238 mm
Depth232 mm

Product details

Its headline rating is 700 A in AC-3 utilisation category (IEC 60947-4-1), which translates to switching a 250 kW induction motor at 400 V AC — the AC-3 curve governs starting and plugging of squirrel-cage motors, where the contactor makes and breaks the motor at full load. For resistive loads (AC-1), the thermal current Ith is 700 A at 50 Hz, with 88 W dissipation per pole. The 400 V DC coil (Uc) holds at 0.85 to 1.1 Uc and drops out between 0.2 and 0.35 Uc, so verify your control supply stays within that band at 55 °C ambient. Mounting is plate-based (not DIN rail), with power circuit connections via bar (40 x 5 mm busbar) or ring lugs up to 240 mm². The control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid. IP20 front-face protection with shrouds per IEC 60529 means it's suited for enclosed panel installation, not washdown environments.

This part is in EOL hot phase — the manufacturer has announced end-of-life.

The LC1F500VD is certified to EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Overvoltage category III. Protective treatment TH (tropicalisation) is standard.

Frequently asked questions

What compliance documentation does LC1F500VD carry?

The contactor is certified to EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V (IEC) and 1500 V (VDE 0110 group C). Protective treatment TH is standard.

MPN
LC1F500VD