The Schneider Electric TeSys K LC2K12015D7 is a reversing contactor — three poles, preassembled with a reversing power busbar so you don't have to wire the interlock yourself. The coil pulls in on 42 V AC, and there's one normally-closed auxiliary contact built in. The 12 A at 440 V covers a lot of small three-phase motors you'd find on a production line. This is a control-duty part, not a power-distribution breaker. It lives inside a panel, IP20-finger-safe, and it's meant to be switched on and off frequently — that's the whole job of a contactor.
Schneider TeSys K LC2K12015D7 reversing contactor, 3P, AC-3
MPNLC2K12015D7
Active
Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 42 V AC coil, IP20.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control Resistive load |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-1 AC-3 AC-4 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings on this reversing contactor?
Three poles, AC-3 motor rating 12 A at 440 V, AC-1 resistive rating also available. Coil is 42 V AC 50/60 Hz. Rated operational voltage of the power circuit is 690 V AC.
What approvals does the LC2K12015D7 carry?
It carries VDE 0106 for IP20 finger protection, UL 94 V1 flame retardance, and NF F 16-101/102 for railway fire safety. The protective treatment meets IEC 60068 and DIN 50016 for corrosion resistance.
MPN
LC2K12015D7