Skip to main content
Schneider Electric LC2K16017Y7 — Contactors

TeSys K LC2K16017Y7 reversing contactor, 3P, AC-3 16 A, 660-

MPNLC2K16017Y7
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 660-690 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K16017Y7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16017Y7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K16017Y7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16017Y7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16017Y7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K16017Y7 is a TeSys K reversing contactor from Schneider Electric — a 3-pole, 3 NO power pole contactor rated for AC-3 duty at 16 A up to 440 V, with a 660-690 V AC 50/60 Hz coil. The IP20 finger-safe enclosure (VDE 0106) suits it for panel-mount applications where operators need protection from accidental contact.

The AC-3 rating of 16 A at <=440 V is the motor-switching current — this contactor handles reversing duty on three-phase induction motors up to roughly 7.5 kW at 400 V. The 660-690 V coil voltage is unusual: it's a direct line-voltage coil, not a 24 VDC or 230 V control circuit coil. That means the coil energizes straight from the motor supply, saving a control transformer but requiring the control wiring to be rated for the same voltage class. The AC-4 utilisation category also covers inching and plugging duty, so it can handle frequent reversals under load.

The preassembled busbar saves a wiring step.

Frequently asked questions

What is the depth of this contactor?

The depth is 57 mm.

What range does this part belong to?

It is part of the TeSys range, specifically the TeSys K series of contactors.

MPN
LC2K16017Y7