The preassembled reversing busbar eliminates the need for external cross-wiring between two contactors, which reduces wiring errors and saves about 20–30 mm of DIN-rail width compared to a field-built reversing pair. Operating altitude is 2000 m without derating; above that, the dielectric withstand and thermal dissipation both drop, so consult the thermal derating curve.
Schneider Electric LC2K1601C72 TeSys K Reversing Contactor,
Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NC, 36 V AC coil, preassembled with reversing power busbar.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-4 AC-3 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings for this reversing contactor?
AC-3 rating at ≤440 V is 16 A. Coil is 36 V AC 50/60 Hz. Rated operational voltage on the power circuit is 690 V AC. It has one NC auxiliary contact and IP20 finger-safe protection.
What compliance documentation does Schneider provide for this part?
The part carries V1 flame retardance per UL 94, plus compliance to NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. It also meets IEC 60068 for shock and vibration robustness. Standard Schneider declarations for RoHS and REACH are available on request.
What is the depth of this contactor?
Listed depth is 57 mm. Overall dimensions are 90 mm wide × 58 mm high × 57 mm deep.