Schneider Electric LC3K06U7 — Contactors

Schneider TeSys K LC3K06U7 Star Delta Starter, 6 A, 240 V AC

MPNLC3K06U7
Active

Schneider Electric TeSys K, star delta starter, 3 x 3P (3 NO), 6 A, 240 V AC coil, AC-3 motor control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC3K06U7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3K06U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3K06U7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3K06U7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed, on X axis: 10 Gn for 11 ms Shocks contactor opened, on X axis: 6 Gn for 11 ms Shocks contactor closed, on Y axis: 15 Gn for 11 ms Shocks contactor opened, on Y axis: 10 Gn for 11 ms Shocks contactor closed, on Z axis: 15 Gn for 11 ms Shocks contactor opened, on Z axis: 10 Gn for 11 ms
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC3K06U7 — Other specifications
ParameterValue
Device short nameLC3K
Device presentationPre-wired
Power pole contact composition3 x 3 NO
Ambient air temperature for storage-50...80 °C

Product details

The Schneider Electric TeSys K LC3K06U7 is a pre-wired star delta starter built for motor control under AC-3 utilisation category — the duty class that governs switching of squirrel-cage motors during start and run. Three power poles, each 3 NO, rated at 6 A. The 240 V AC coil is designed for direct panel supply without a control transformer step-down. This is not a bare contactor; it is a factory-assembled star-delta transition unit, meaning the internal wiring and timing logic for the transition from star to delta are integrated. That saves panel-build labour and reduces wiring error risk on repetitive motor starts — a poka-yoke advantage for lines where traceability matters.

The AC-3 rating at 6 A defines the motor full-load current it can switch without accelerated contact wear. For a 400 V three-phase motor, that corresponds roughly to a 3 kW load — typical for small conveyors, pumps, or fan starters in a Tier-1 cell. The 240 V AC coil pull-in holds reliably across the 0.85–1.1 Un range common in industrial supplies. Mechanical robustness is documented: the contactor withstands 4 Gn vibration when closed (5–300 Hz) and 15 Gn shock on the Y and Z axes when closed. That covers the vibration profile of a machine-mounted panel next to a press or conveyor drive.

Frequently asked questions

What compliance documentation does this brand provide for LC3K06U7?

The part carries UL 94 V1 flame retardance and compliance with NF F 16-101 and NF F 16-102 for fire-smoke behaviour. Standard Schneider Electric declarations for RoHS and REACH are available on request as part of the product documentation package.