Skip to main content
Schneider Electric LC3K09E7 — Contactors

TeSys K LC3K09E7 Star Delta Starter, 9 A, 48 V AC Coil

MPNLC3K09E7
Obsolete

Schneider Electric TeSys K, star delta starter, 3 x 3P (3 NO), 9 A, 48 V AC coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3K09E7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3K09E7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3K09E7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3K09E7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed, on X axis: 10 Gn for 11 ms Shocks contactor opened, on X axis: 6 Gn for 11 ms Shocks contactor closed, on Y axis: 15 Gn for 11 ms Shocks contactor opened, on Y axis: 10 Gn for 11 ms Shocks contactor closed, on Z axis: 15 Gn for 11 ms Shocks contactor opened, on Z axis: 10 Gn for 11 ms
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC3K09E7 — Other specifications
ParameterValue
Device short nameLC3K
Device presentationPre-wired
Power pole contact composition3 x 3 NO
Ambient air temperature for storage-50...80 °C

Product details

The Schneider Electric LC3K09E7 is a TeSys K star delta starter, pre-wired with three 3-pole power poles (3 x 3 NO) and a 48 V AC coil. It's built for motor control under AC-3 utilization category — the standard for squirrel-cage motors during starting, switching off running motors, and plugging.

The AC-3 rating at 9 A is the number that decides whether this starter fits your motor. AC-3 means it's rated for making and breaking motor currents — higher than the resistive AC-1 rating for the same contactor. The 48 V AC coil is a specific control voltage; if your panel runs 24 V DC or 110 V AC, this coil won't pull in. Flame retardance meets V1 per UL 94, so it's rated for flammability in enclosed panels.

Integration notes

The pre-wired design saves a few wiring steps on the bench, but the 3 x 3P pole arrangement means you're committing to three separate contactor poles in the star-delta configuration — not a single 3-pole contactor. Operating altitude is 2000 m without derating; above that you'd need to account for reduced dielectric strength. The protective treatment (TC per IEC 60068 and DIN 50016) suggests it's tested for condensation and corrosive atmospheres, which is good for industrial environments but doesn't replace an IP65 enclosure.

Frequently asked questions

What is the LC3K09E7's range and product name?

It belongs to the TeSys range and the product name is TeSys K.

What compliance documentation does this part carry?

The part is rated V1 conforming to UL 94 for flame retardance, and meets Requirement 2 of NF F 16-101 and NF F 16-102 for fire behavior. The protective treatment complies with IEC 60068 and DIN 50016 for environmental resistance.

MPN