Rated AC-3 at 12 A up to 440 V, it handles reversing duty on small three-phase motors (pumps, conveyors, fans) within that current envelope. The 110 V AC coil matches standard control voltages in many panel designs.
AC-4 covers inching and reversing duty, which is harder on the contacts; AC-1 covers resistive loads. The 110 V AC coil is standard for North American and many European control circuits. IP20 finger-safe terminals (per VDE 0106) suit enclosed panel mounting.
Mechanical and environmental robustness
Built to take vibration and shock on a machine: the contactor withstands 4 Gn vibration (5–300 Hz) when closed, and shock up to 15 Gn on Y and Z axes when closed. Flame retardance meets UL 94 V1 and NF F 16-101/102, which matters for rail and industrial compliance. Protective treatment conforms to IEC 60068 and DIN 50016 for damp heat and corrosive atmospheres.